beautypg.com

Technical data – KROHNE OPTIFLUX 5000 Sandwich EN User Manual

Page 26

background image

6

TECHNICAL DATA

26

OPTIFLUX 5000

www.krohne.com

10/2011 - 4000686202 - MA OPTIFLUX 5000 SW R02 en

Installation condtitions

Installation

Take care that flow sensor always fully filled.

For detailed information refer to

Installation on page 11.

Flow direction

Forward and reverse.

Arrow on flow sensor indicates positive flow direction.

Inlet run

≥ 5 DN (without disturbing flow, after a single 90° bend)
≥ 10 DN (after a double bend 2x 90°)
≥ 10 DN (behind a control valve)

Outlet run

≥ 2 DN

Dimensions and weights

For detailed information refer to

Dimensions and weights on page 30.

Materials

Sensor housing

DN2.5...15: stainless steel 1.4408

DN25...100: stainless steel 1.4306

Measuring tube

Ceramic

Connection box

(remote versions only)

Standard:

Standard:

Standard:

Standard:

Polyurethane coated die-cast aluminium

Option:

Option:

Option:

Option:

Stainless steel

Grounding rings

Standard:

Standard:

Standard:

Standard:

Stainless steel

Option:

Option:

Option:

Option:

Hastelloy

®

C, titanium, tantalum

Other materials on request.

Grounding rings can be omitted with virtual reference option for the

IFC 300 converter.

Stud bolts and nuts

Standard:

Standard:

Standard:

Standard:

Steel

Option:

Option:

Option:

Option:

Stainless steel, rubber centering sleeves

Gaskets

FPM / FKM, Gylon, EPDM, Kalrez, PTFE-PF 29, Chemotherm

Other materials on request.

Measuring electrodes

DN2.5...15: Cermet

DN25...100: Platinum

.book Page 26 Monday, October 3, 2011 1:46 PM