beautypg.com

Installation – KROHNE OPTIFLUX 5000 Sandwich EN User Manual

Page 16

background image

3

INSTALLATION

16

OPTIFLUX 5000

www.krohne.com

10/2011 - 4000686202 - MA OPTIFLUX 5000 SW R02 en

3.5.11 Pump

3.5.12 Temperatures

Figure 3-13: Installation after pump

CAUTION!
Protect the device from direct sunlight.

Temperature range

Process [°C]

Ambient [°C]

Process [°F]

Ambient [°F]

min.

max.

min.

max.

min.

max.

min.

max.

Separate flow sensor

-60

180

-40

65

-76

356

-40

149

Compact + IFC 300

-60

140

-40

65

-76

284

-40

149

Compact + IFC 100

-60

140

-40

65

-76

284

-40

149

.book Page 16 Monday, October 3, 2011 1:46 PM