Technical data – KROHNE OPTIFLUX 5000 Sandwich EN User Manual
Page 25
TECHNICAL DATA
6
25
OPTIFLUX 5000
www.krohne.com
10/2011 - 4000686202 - MA OPTIFLUX 5000 SW R02 en
Operating conditions
Temperature
Temperature
Temperature
Temperature
Process temperature
Compact version: -40...+140°C / -40... +284°F
Remote version: -40...+180°C / -40...+356°F
For Ex versions different temperature ranges are applicable. Please see the
relevant Ex documentation for details.
Maximum temperature
change (shock)
120°C / 248°F
Ambient temperature
-40…+65°C / -40…+149°F
For Ex versions different temperature ranges are applicable. Please see the
relevant Ex documentation for details.
Storage temperature
-50…+70°C / -58…+158°F
Pressure
Pressure
Pressure
Pressure
Ambient
Atmospheric
Nominal flange pressure
EN 1092-1
Standard:
Standard:
Standard:
Standard:
DN100: PN 16
DN2.5...80: PN 40
Option:
Option:
Option:
Option:
DN100: PN 25
ASME B16.5
Standard:
Standard:
Standard:
Standard:
1/10...4": 150 lb
Option:
Option:
Option:
Option:
1/10...4": 300 lb
Vacuum load
0 mbar / 0 psi
Pressure ranges for
secondary containment
Pressure resistant up to 40 bar / 580 psi
Burst pressure up to approx. 160 bar / 2320 psi
Chemical properties
Chemical properties
Chemical properties
Chemical properties
Physical condition
Liquids
Electrical conductivity
Non water:
Non water:
Non water:
Non water:
DN25...100: ≥ 1 μS/cm
DN4...15: ≥ 5 μS/cm
DN2.5: ≥ 10 μS/cm
Demineralised cold water:
Demineralised cold water:
Demineralised cold water:
Demineralised cold water:
DN2.5...100: ≥ 20 μS/cm
Permissible gas content
(volume)
≤ 5%
Permissible solid content
(volume)
IFC 100: ≤ 10%
IFC 300: ≤ 70%
Recommended flow
velocity
-12...+12 m/s / -40...+40 ft/s
.book Page 25 Monday, October 3, 2011 1:46 PM