background image

TECHNICAL DATA

6

25

OPTIFLUX 5000

www.krohne.com

10/2011 - 4000686202 - MA OPTIFLUX 5000 SW R02 en

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

Compact version: -40...+140°C / -40... +284°F

Remote version: -40...+180°C / -40...+356°F

For Ex versions different temperature ranges are applicable. Please see the

relevant Ex documentation for details.

Maximum temperature

change (shock)

120°C / 248°F

Ambient temperature

-40…+65°C / -40…+149°F

For Ex versions different temperature ranges are applicable. Please see the

relevant Ex documentation for details.

Storage temperature

-50…+70°C / -58…+158°F

Pressure

Pressure

Pressure

Pressure

Ambient

Atmospheric

Nominal flange pressure

EN 1092-1

Standard:

Standard:

Standard:

Standard:

DN100: PN 16

DN2.5...80: PN 40

Option:

Option:

Option:

Option:

DN100: PN 25

ASME B16.5

Standard:

Standard:

Standard:

Standard:

1/10...4": 150 lb

Option:

Option:

Option:

Option:

1/10...4": 300 lb

Vacuum load

0 mbar / 0 psi

Pressure ranges for

secondary containment

Pressure resistant up to 40 bar / 580 psi

Burst pressure up to approx. 160 bar / 2320 psi

Chemical properties

Chemical properties

Chemical properties

Chemical properties

Physical condition

Liquids

Electrical conductivity

Non water:

Non water:

Non water:

Non water:

DN25...100: ≥ 1 μS/cm

DN4...15: ≥ 5 μS/cm

DN2.5: ≥ 10 μS/cm

Demineralised cold water:

Demineralised cold water:

Demineralised cold water:

Demineralised cold water:

DN2.5...100: ≥ 20 μS/cm

Permissible gas content

(volume)

≤ 5%

Permissible solid content

(volume)

IFC 100: ≤ 10%

IFC 300: ≤ 70%

Recommended flow

velocity

-12...+12 m/s / -40...+40 ft/s

.book Page 25 Monday, October 3, 2011 1:46 PM