KROHNE UFC 030 PROFIBUS PA User Manual
Page 2

Supplementary documentation UFC030 with PROFIBUS-PA
KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5
D-47058 Duisburg
2/17
Tel.: 0203-301 309
Fax: 0203-301389 · e-mail: [email protected]
CONTENTS:
1
GENERAL...................................................................................................................................................................................................3
2
ITEMS INCLUDED WITH SUPPLY .................................................................................................................................................3
3
SOFTWARE HISTORY..........................................................................................................................................................................3
4
PROFIBUS -PA...........................................................................................................................................................................................3
4.1
P
ROFILES
.................................................................................................................................................................................................4
4.2
S
ERVICES
.................................................................................................................................................................................................4
4.3
GSD
F
ILES
...............................................................................................................................................................................................4
4.3.1
Manufacturer specific GSD file: KROHF501.GSD........................................................................................................................4
4.3.2
Profile specific GSD file: PA_9741.GSD.........................................................................................................................................6
4.4
C
YCLIC DATA EXCHANGE
.....................................................................................................................................................................6
4.5
D
ATA
S
TRUCTURE OF
F
UNCTION
B
LOCK
O
UTPUT
V
ALUES
............................................................................................................6
4.5.1
Float Value .............................................................................................................................................................................................6
4.5.2
Status Value............................................................................................................................................................................................7
4.6
D
IAGNOSIS
...............................................................................................................................................................................................8
5
ELECTRICAL CONNECTION............................................................................................................................................................8
5.1
I
NTERCONNECTION OF DEVICES IN THE HAZARDOUS AREA
.............................................................................................................8
5.2
B
US CABLE
..............................................................................................................................................................................................8
5.3
S
HIELDING AND GROUNDING
................................................................................................................................................................8
5.4
PROFIBUS-PA
CONNECTION
..............................................................................................................................................................9
6
MENU SETTINGS FOR PROFIBUS -PA ..........................................................................................................................................9
7
IMPORTANT NOTES .............................................................................................................................................................................9
7.1
P
ARAMETER
“
METER
_
TYPE
”
OF
UFC030...........................................................................................................................................9
8
TECHNICAL DATA ................................................................................................................................................................................10
9
DEVICE DESCRIPTION FOR THE SIMATIC PROCESS DEVICE MANAGER (PDM) ...............................................11
9.1
I
NSTALLATION
........................................................................................................................................................................................11
9.2
O
PERATING
..............................................................................................................................................................................................11