beautypg.com

KROHNE OPTISOUND 3040 C 4wire EN User Manual

Page 20

background image

Fig. 13: Transducers on traverse crane

Do not mount the instruments in or above the filling stream.

Make sure that you detect the product surface and not the

inflowing product.

Fig. 14: Inflowing material

Through the action of filling, stirring and other processes in the

vessel, dense foams which considerably damp the emitted

signals may form on the product surface.
If foams are causing measurement errors, the sensor should

be used in a standpipe or, alternatively, the more suitable

guided radar sensors (TDR) should be used.
Guided radar is not influenced by foam generation and is

particularly suitable for such applications.

Inflowing material

Foam

20

OPTISOUND 3040 C - 4 ... 20 mA/HART - four-wire

Mounting

30515

-EN
-050914