7 Tighten the screws (5) on the cylinder moderately with a

hexagon spanner (size 4)

8 Loosen the screw of the swivelling holder (3) with a fork

spanner (SW 13)

9 Direct the sensor with the swivelling holder to the

measured product

10 Fasten the swivelling holder with screw (3), torque max.

20 Nm

11 Secure screw (3) with lacquer or similar to ensure

permanent tightness of the swivelling holder

12 Rotate the connection cylinder in such a way that the cable

entry points downwards (moisture can drain off). Fasten

the cylinder with screws (5); torque max. 5 Nm

13 Insert the plug at the end of the transducer cable into the

socket on the remote electronics

1

2

3

4

5

Fig. 6: Assembling – version C

1

Groove for locking the connection cylinder

2

Marking notch

3

Screw of swivelling holder (hexagon SW 13)

4

Screws of fixing ring (hexagon spanner - size 4)

5

Screws of connection cylinder (hexagon spanner - size 4)

Version D is supplied in three parts:

l

Transducer

l

Transducer cable

l

electronics for wall mounting