KROHNE IFC 090F Converter EEx-ATEX EN User Manual

Page 18

background image

ALTOFLUX IFC 090 F-EEx and ALTOFLUX IFC 090 F / i-EEx

18

Connection diagrams 5 to 8 of the intrinsically safe signal in-/outputs

5

Pulse output P

passive

6

Status output S

active

Versions:

Ex-i1, Ex-i4, Ex-i6, Ex-i8

Version: Ex-i5

U

ext

= 6 - 30 V

U

int

= 20 V DC

I

max

≤ 110 mA

R

int

= 260

for active EC

U

L

= 20×R

L

/ (260+R

L

)

IFC 090 i-EEx

IFC 090 i-EEx

hazardous area

hazardous area

safe area or

safe area or

hazardous area (

*

)

hazardous area (

*

)

active counter

7

Status output S

passive

8

Control input C

active

Versions:

Ex-i1, Ex-i4, Ex-i6, Ex-i8

Version: Ex-i5

U

ext

= 6 - 30 V

U

int

= 20 V DC

I

max

≤ 110 mA

I

contact

≤ 6 mA

Connection to terminals B1/B1

⊥ and/or

B2/B2

IFC 090 i-EEx

IFC 090 i-EEx

hazardous area

hazardous area

safe area or

safe area or

hazardous area (

*

)

hazardous area (

*

)



(

*

) Important note:

Only if the measuring devices are also explosion protected !