2

INSTALLATION

14

OPTIFLEX 1100 C

www.krohne.com

01/2012 - 4001226201 - QS OPTIFLEX 1100 R01 en

2.4 How to install a device with a threaded connection

Equipment needed:

• Gasket (not supplied with G (ISO 228) threaded connections)
• 34 mm wrench (not supplied)

2.5 How to turn or remove the signal converter

How to remove the signal converter

• Loosen the lock screw with a 5 mm wrench.
• Remove the signal converter from the probe assembly.
• Put the cover 3 on the probe assembly.

Figure 2-14: How to turn or remove the signal converter

1 Signal converter
2 Process connection and probe assembly
3 Cover for the coaxial hole on top of the process connection assembly

CAUTION!
When the housing is attached to the process connection assembly, make sure that the lock
screw is tight.