beautypg.com

Temperature limits – KROHNE OPTISONIC 7300 Ex EN User Manual

Page 17

background image

TEMPERATURE LIMITS

2

17

OPTISONIC 7300 / 8300

www.krohne.com

05/2012 - 7312262200 - AD EX OPTISONIC 7300/8300 R02

2.4 OPTISONIC 7000...-Ex

The OPTISONIC 7000-Ex and OPTISONIC 7000 XT-Ex have an ambient temperature in the range
of -40...+70°C. The maximum process medium temperature is listed in the table below.

2.5 OPTISONIC 8000...-Ex

The OPTISONIC 8000...-Ex high temperature (steam) flow sensor has an ambient temperature in
the range of -40...+60°C. The maximum process medium temperature is listed in the table
below.

CAUTION!
The temperature data below only applies to the meters with ultrasonic gas transducers made of
titanium (types G7.01 and G7.04). For the partly encapsulated transducer types G5.nn and G6.nn,
refer to Technical data on page 10

.

Temperature class

Maximum process temperature [ºC] at T

a

= 70ºC

Standard design

XT design

T6

80

80

T5

95

95

T4

130

130

T3

180

195

T2

n.a.

220

Temperature class

Maximum process temperature [ºC] at T

a

= 60ºC

T6

80

T5

95

T4

130

T3

195

T2

290

T1

440