Supplementary Handbook IFC 300 HART, FC375, AMS, PDM, DTM

File

Device

View

Options

Help

Display

Yt Diagram

Outputs

Device Status

Circuit Board Info

-----------------------------------
Toolbar
Status Bar
-----------------------------------
Update

IFC 300 HART Menu Tree PDM

Menu Bar

device
• C number

Rd

• device serial no.

Rd

• electronic serial no.

Rd

HART:
• tag
• manufacturer

Rd

• model

Rd

• device ID

Rd

standard
overview:
• Primary variable out of limits
• Non-primary variable out of limits
• AO outside the operating range limits
• Analog Output in fixed mode
• Cold start
• Configuration changed
• Field device malfunction

failure (application):
• F application error
• F empty pipe
• F flow rate too high
• F field frequency too high
• F DC offset
• F open circuit A/B/C
• F over range A/B/C (current)
• F over range A/B/D (pulse)
• F active settings
• F factory settings
• F backup 1/2 settings

failure
failure (device):
• F error in device
• F IO1
• F parameter
• F IO2
• F configuration
• F display
• F sensor electronic
• F sensor global

off-spec / checks / info
out of specification:
• S out of specification
• S pipe not full
• S empty pipe
• S linearity
• S flow profile
• S electrode noise
• S gain error
• S electrode symmetry
• S field coil broken
• S field coil bridged
• S field current deviation

information:
• I counter 1 stopped
• I counter 2 stopped
• I power fail
• I control input A active
• I control input B active
• I over range display 1
• I over range display 2
• I backplane sensor
• I backplane settings
• I backplane difference
• I optical interface
• I counter 3 stopped

failure (device):
• F sensor local
• F field current local
• F current output A
• F current output B
• F current output C
• F software user interface
• F hardware settings
• F hardware detection
• F RAM/ROM error IO 1
• F RAM/ROM error IO 2

• universal revision

Rd

• device revision

Rd

• software revision

Rd

• hardware revision

Rd

• date

Rd

• write protect

Rd

• final assembly no.

Rd

• sensor serial no.

Rd

• S field frequency too high
• S electronic temperature
• S coil temperature
• S overflow counter 1
• S overflow counter 2
• S backplane invalid
• S overflow counter 3

check request:
• C checks in progress
• C test sensor

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Cust

Custody Lock protected

Loc

Local PDM, affects only PDM views

1

2

KROHNE IFC 300 HA 45e30201 (3/6)
04.06

HART_Suppl_IFC300_V0201.DOC

04/2007

20/23