Ifc 300 hart menu tree ams – KROHNE IFC 300 Converter HART 0201 User Manual
Page 14
Supplementary Handbook IFC 300 HART, FC375, AMS, PDM, DTM
Configure
Compare
Clear Offline
-----------------------------------
Status/Conditions
Process Variables
Scan Device
-----------------------------------
Calibration Management
Diagnostics and Test
Calibrate
Reset
Basic Configuration
-----------------------------------
Rename
Unassign
Assign / Replace
-----------------------------------
Audit Trail
Record Manual Event
Drawings / Notes ...
Help ...
IFC 300 HART Menu Tree AMS
I/O terminals A/B/C/D
• terminals
• range 100%
Cust
• range 0%
Cust
• ext. range max
Cust
• ext. range min
Cust
• error current
Cust
• error condition
Cust
• special function
Cust
• rc threshold
Opt, Cust
• rc hysteresis
Opt, Cust
counter
counter 2:
• function
Cust
• measurement
Opt, Cust
• lfc threshold
Opt, Cust
• lfc hysteresis
Opt, Cust
• time constant
Opt, Cust
• preset value
Opt, Cust
frequency output
Opt
:
• measurement
Cust
• limitation max
Cust
• limitation min
Cust
• time constant
• polarity
Cust
• lfc threshold
Cust
• lfc hysteresis
Cust
• range max
Cust
• range min
Cust
• pulse shape
Cust
• pulse width
Cust
• 100% pulse rate
Cust
• invert signal
Cust
• special function
Opt, Cust
• phase shift wrt. B
Opt, Cust
pulse output
Opt
:
• measurement
Cust
• time constant
• polarity
Cust
• lfc threshold
Cust
• lfc hysteresis
Cust
• pulse value unit
Cust
• value p. pulse
Cust
• pulse shape
Cust
• pulse width
Cust
• max pulse rate
Cust
• invert signal
Cust
• special function
Opt, Cust
• phase shift wrt. B
Opt, Cust
status output
Opt
:
• mode
• output A
Opt
• output B
Opt
• output C
Opt
• output D
Opt
• invert signal
limit switch
Opt
:
• measurement
• time constant
• polarity
• threshold
• hysteresis
• invert signal
control input
Opt
:
• mode
Cust
• invert signal
current output
Opt
:
• measurement
Cust
• limitation max
Cust
• limitation min
Cust
• time constant
Cust
• polarity
Cust
• lfc threshold
Cust
• lfc hysteresis
Cust
• range max
Cust
• range min
Cust
counter 1:
• function
Cust
• measurement
Opt, Cust
• lfc threshold
Opt, Cust
• lfc hysteresis
Opt, Cust
• time constant
Opt, Cust
• preset value
Opt, Cust
Designations:
Opt
Optional, dependent on device
implementation / configuration
Rd
Read-only
Cust
Custody Lock protected
Loc
Local AMS, affects only AMS views
counter 3
Opt
:
• function
Cust
• measurement
Opt, Cust
• lfc threshold
Opt, Cust
• lfc hysteresis
Opt, Cust
• time constant
Opt, Cust
• preset value
Opt, Cust
5
5
4
1,3