Ifc 300 hart menu tree ams – KROHNE IFC 300 Converter HART 0201 User Manual

Page 16

background image

Supplementary Handbook IFC 300 HART, FC375, AMS, PDM, DTM

Configure

Compare

Clear Offline

-----------------------------------

Status/Conditions

Process Variables

Scan Device

-----------------------------------

Calibration Management

Diagnostics and Test

Calibrate

Reset

Basic Configuration

-----------------------------------

Rename

Unassign

Assign / Replace

-----------------------------------

Audit Trail

Record Manual Event

Drawings / Notes ...

Help ...

Overview

Standard:
• Primary variable out of

limits

• Non-primary variable out

of limits

• Primary variable analog

output saturated

• Primary variable analog

output fixed

• Cold start
• Configuration changed
• Field device malfunction

Failure (device)

• F error in device
• F IO1
• F parameter
• F IO2
• F configuration
• F display
• F sensor electronic
• F sensor global
• F sensor local

IFC 300 HART Menu Tree AMS

Out of specification

• S out of specification
• S pipe not full
• S empty pipe
• S linearity
• S flow profile
• S electrode noise
• S gain error
• S electrode symmetry

Failure (application)

• F application error
• F empty pipe
• F flow rate too high
• F field frequency too high
• F DC offset
• F open circuit A
• F open circuit B
• F open circuit C

Check req. & Information

check request:
• C checks in progress
• C test sensor

information:
• I counter 1 stopped
• I counter 2 stopped
• I counter 3 stopped
• I power fail
• I control input A active
• I control input B active
• I over range display 1
• I over range display 2
• I backplane sensor
• I backplane settings
• I backplane difference
• I optical interface

• F over range A (current)
• F over range B (current)
• F over range C (current)
• F over range A (pulse)
• F over range B (pulse)
• F over range D (pulse)
• F active settings
• F factory settings
• F backup 1 settings
• F backup 2 settings

• F field current local
• F current output A
• F current output B
• F current output C
• F software user interface
• F hardware settings
• F hardware detection
• F RAM/ROM error IO 1
• F RAM/ROM error IO 2

• S field coil broken
• S field coil bridged
• S field current deviation
• S field frequency too high
• S electronic temperature
• S coil temperature
• S overflow counter 1
• S overflow counter 2
• S overflow counter 3
• S backplane invalid

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Cust

Custody Lock protected

Loc

Local AMS, affects only AMS views

1,2,3

5

5

KROHNE IFC 300 HA 45e30201 (4/5)
04/06

HART_Suppl_IFC300_V0201.DOC

04/2007

16/23