Ifc 300 hart menu tree ams – KROHNE IFC 300 Converter HART 0201 User Manual
Page 16
Supplementary Handbook IFC 300 HART, FC375, AMS, PDM, DTM
Configure
Compare
Clear Offline
-----------------------------------
Status/Conditions
Process Variables
Scan Device
-----------------------------------
Calibration Management
Diagnostics and Test
Calibrate
Reset
Basic Configuration
-----------------------------------
Rename
Unassign
Assign / Replace
-----------------------------------
Audit Trail
Record Manual Event
Drawings / Notes ...
Help ...
Overview
Standard:
• Primary variable out of
limits
• Non-primary variable out
of limits
• Primary variable analog
output saturated
• Primary variable analog
output fixed
• Cold start
• Configuration changed
• Field device malfunction
Failure (device)
• F error in device
• F IO1
• F parameter
• F IO2
• F configuration
• F display
• F sensor electronic
• F sensor global
• F sensor local
IFC 300 HART Menu Tree AMS
Out of specification
• S out of specification
• S pipe not full
• S empty pipe
• S linearity
• S flow profile
• S electrode noise
• S gain error
• S electrode symmetry
Failure (application)
• F application error
• F empty pipe
• F flow rate too high
• F field frequency too high
• F DC offset
• F open circuit A
• F open circuit B
• F open circuit C
Check req. & Information
check request:
• C checks in progress
• C test sensor
information:
• I counter 1 stopped
• I counter 2 stopped
• I counter 3 stopped
• I power fail
• I control input A active
• I control input B active
• I over range display 1
• I over range display 2
• I backplane sensor
• I backplane settings
• I backplane difference
• I optical interface
• F over range A (current)
• F over range B (current)
• F over range C (current)
• F over range A (pulse)
• F over range B (pulse)
• F over range D (pulse)
• F active settings
• F factory settings
• F backup 1 settings
• F backup 2 settings
• F field current local
• F current output A
• F current output B
• F current output C
• F software user interface
• F hardware settings
• F hardware detection
• F RAM/ROM error IO 1
• F RAM/ROM error IO 2
• S field coil broken
• S field coil bridged
• S field current deviation
• S field frequency too high
• S electronic temperature
• S coil temperature
• S overflow counter 1
• S overflow counter 2
• S overflow counter 3
• S backplane invalid
Designations:
Opt
Optional, dependent on device
implementation / configuration
Rd
Read-only
Cust
Custody Lock protected
Loc
Local AMS, affects only AMS views
1,2,3
5
5
KROHNE IFC 300 HA 45e30201 (4/5)
04/06
HART_Suppl_IFC300_V0201.DOC
04/2007
16/23