Supplementary Handbook IFC 300 HART, FC375, AMS, PDM, DTM

IFC 300 HART Menu Tree FC375

1 process input

2 I/O

3 I/O Counter

4 I/O HART
5 device

1 hardware

2 A

3 B

4 C

5 D

1 terminals A

Cust

2 terminals B

Cust

3 terminals C

Cust

4 terminals D

Cust

current output

Opt

:

1 range 0%

Cust

2 range 100%

Cust

3 ext. range min

Cust

4 ext. range max

Cust

5 error current

Cust

6 error condition

Cust

7 measurement

Cust

8 range min

Cust

9 range max

Cust

10 polarity

Cust

11 limit min

Cust

12 limit max

Cust

13 lfc threshold

Cust

14 lfc hysteresis

Cust

15 time constant

Cust

16 special function

Cust

17 rc threshold

Opt, Cust

18 rc hysteresis

Opt, Cust

19 information x

frequency output

Opt

:

1 pulse shape

Cust

2 pulse width

Cust

3 100% pulse rate

Cust

4 measurement

Cust

5 range min

Cust

6 range max

Cust

7 polarity

Cust

8 limit min

Cust

9 limit max

Cust

10 lfc threshold

Cust

11 lfc hysteresis

Cust

13 time constant
14 invert signal

Cust

15 special function

Opt, Cust

16 phase shift w. B

Opt, Cust

17 information x

1 function

Cust

2 measurement

Opt, Rd

3 select measurement

Opt, Cust

4 lfc threshold

Opt, Cust

5 lfc hysteresis

Opt, Cust

6 time constant

Opt, Cust

7 preset value

Opt, Cust

8 reset counter x

Opt, Cust

9 set counter x

Opt, Cust

10 information

pulse output

Opt

:

1 pulse shape

Cust

2 pulse width

Cust

3 max pulse rate

Cust

4 measurement

Cust

5 pulse value unit

Cust

6 value p. pulse

Cust

7 polarity

Cust

8 lfc threshold

Cust

9 lfc hysteresis

Cust

10 time constant
11 invert signal

Cust

12 special function

Opt, Cust

13 phase shift w. B

Opt, Cust

14 information x

status output

Opt

:

1 mode
2 output A

Opt

output B

Opt

output C

Opt

output D

Opt

3 invert signal
4 information x

limit switch

Opt

:

1 measurement
2 threshold
3 hysteresis
4 polarity
5 time constant
6 invert signal
7 information x

control input

Opt

:

1 mode

Cust

2 invert signal
3 information x

KROHNE IFC 300 HA 45e30201 (3/4)
04/06

1 dynamic

variables

2 quick setup
3 test

4 setup

1

2

1 counter 1

2 counter 2

3 counter 3

Opt

4

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Cust

Custody Lock protected

Loc

Local FC375,

affects only FC375 views

HART_Suppl_IFC300_V0201.DOC

04/2007

11/23

This manual is related to the following products: