beautypg.com

Local sensing (factory default), Remote sensing select, Figure 3. remote sensing – KEPCO KLP Series Quick Start Guide, P/N 228-1773 User Manual

Page 6: Figure 2

background image

6

228-1773 REV 1

091713

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

LOCAL SENSING (FACTORY DEFAULT). Unit is shipped with local sensing jumpers installed: +S
connected to +M and –M connected to –S (see Figure 2).

FIGURE 2. KLP SERIES, REAR PANEL VIEW, JUMPERS INSTALLED FOR LOCAL SENSING

REMOTE SENSING SELECT. First remove the factory-installed local sensing jumpers between +S
and +M and between –M and –S. Then connect the +S and –S lines at the load, observing proper polar-
ity (see Figure 3). A high frequency bypass network consisting of two capacitors connected across the
error sensing point as shown in Figure 3 is recommended to reduce noise in the sense loop.

FIGURE 3. REMOTE SENSING