Output characteristics, Environmental characteristics, General characteristics – KEPCO JBW 10W Series User Manual
Page 2

2
228-1412 REV 5
061510
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
http://www.kepcopower.com email: [email protected]
LEAKAGE CURRENT: Cold start:
100V a-c and 60 Hz (single pole switching):
0.75mA max, 0.1mA typ
240V a-c and 60 Hz (single pole switching in confor-
mance to UL 1950/IEC 950):
0.75mA max, 0.15mA typ
POWER FACTOR: Meets EN 61000-3-2, Class D
100V a-c: 0.6 typ.
240V a-c: 0.45 typ.
OUTPUT CHARACTERISTICS:
SOURCE EFFECT: (85 to 265 Va-c)
0.4% max.
LOAD EFFECT: measured at sensing terminals
(0% - 100% load change)
0.8% max.
TEMPERATURE EFFECT: (-10 to 50°C)
1.0% max.
TIME EFFECT OR DRIFT: (1/2 to 8 hr. at 25°C)
0.4% max.
TRANSIENT RECOVERY: A step load change from
50% to 100% of rated load in 50 microseconds or more
produces no more than 4% output voltage excursion.
Temperature range from -10 to 50°C.
HOLD UP TIME: Condition: 100% output load. Upon
input interruption the output is maintained for:
100 Va-c: 15mS typ. (JBW 03-2R0: 20mS typ.)
240 Va-c: 140mS typ. (JBW 03-2R0: 190mS typ.)
START UP TIME:
700mS max. 200mS typ. at 100 Va-c, 240 Va-c
OVERVOLTAGE PROTECTION: Fixed, factory set.
See Table 1. The overvoltage circuit is set by Zener diode
clamp, latching could occur.
OVERCURRENT: Square type, output voltage returns
to rated level upon removal of cause of malfunction (long
term overcurrent could damage unit).
ENVIRONMENTAL CHARACTERISTICS
OPERATING TEMPERATURE: -10 to 60°C (start up
-20 to -10°C). See the derating, Figure 1.
STORAGE TEMPERATURE: -30°C to + 75°C.
COOLING: Natural convection. Do not allow the power
supply to become dust covered because that will
decrease the cooling efficiency of the unit and cause insu-
lation to deteriorate.
ORIENTATION: Vertical or horizontal (see Figure 2).
HUMIDITY: 20% to 90% relative humidity, operating
and storage, noncondensing, wet bulb temperature < or =
35°C.
VIBRATION: Three axes, one hour each, sweep time
10 min., nonoperating.
5-10 Hz., 10 mm amplitude
10-200 Hz., 2G (19.6m/s
2
) acceleration
SHOCK: Three axes, 60G (588m/s
2
), 11 mS ±5mSec
pulse duration, three shocks each axis, nonoperating, 1/2
sine pulse.
GENERAL CHARACTERISTICS
WITHSTANDING VOLTAGE: (at 5 to 35°C ambient,
45 to 85% relative humidity, cutout current 10 mA):
Between input and output terminals:
3.0 KV a-c for 1 minute.
Between input and chassis:
2000V a-c for 1 minute.
Between output terminals and chassis:
500V a-c for 1 minute.
INSULATION RESISTANCE: Between input and out-
put, input and chassis, output and chassis: 100 megohms
minimum (500V d-c, 5 to 35°C ambient, 45 to 85% relative
humidity)
SAFETY: All units designed to meet UL 1950D3, CSA
Electrical Bulletin 22.2NO950-95, and TÜV Rheinland
EN60950 (ambient temp. 50°C). JBW 10W units are CE
marked per the Low Voltage Directive (LVD), EN60950.
[The standards do not apply with DC input operation]
EMI CONDUCTED: FCC Class B, VCCI-B, EN55011-
B, EN55022-B.
ESD: Ground potential area to chassis: 10KV (charge
capacitor 500pF, series resistor 100 Ohms).
SURGE WITHSTAND: 1.2x50µs 3KV pulse, input to
input, input to chassis (operating, 100 Ohm internal series
resistor).
INCOMING NOISE: 1 µs, 2 KV pulse, 50-60Hz, with
50 ohm termination, input to input, input to ground, less
than five minutes, operating, normal operation.
WARRANTY: One year.