KEPCO JBW 10W Series User Manual
10w series, Kepco, 10 watt single output switching power supplies

©2010, KEPCO, INC
1
Data subject to change without notice
228-1412 REV 5
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
http://www.kepcopower.com email: [email protected]
O P E R A T O R M A N U A L
KEPCO
An ISO 9001 Company.
JBW
10W SERIES
10 WATT SINGLE OUTPUT
SWITCHING POWER SUPPLIES
I — INTRODUCTION
SCOPE OF MANUAL. This instruction manual covers
the installation and operation of the Kepco JBW 10W
Series of RoHS (Reduction of Hazardous Substances)
compliant Switching Power Supplies.
DESCRIPTION. The Kepco JBW 10W Series consists of
five models of switching power supplies, with a single out-
put as shown in Table 1. Units may be operated with a
nominal 100 to 120V a-c and 220 to 240V a-c (input voltage
range 85 to 265 Va-c), 50-60 Hz (input frequency range 47-
440Hz) They will also operate on 110V to 370V d-c input.
The JBW 10W Series employs a light weight ferrite core
with 100 KHz switching frequency. Regulation is provided
by pulse width modulation. A FET power stage, operating
in the flyback mode provides a smooth isolated d-c output.
A thermistor circuit prevents excessive turn-on current
surge. Overvoltage protection is provided. Current limiting
with automatic recovery from short circuit is featured. Units
are manufactured on an open frame pc board.
Table 1 contains specifications and operating limits of indi-
vidual JBW 10W Series models. Section II (following) con-
tains specifications and operating limits common to all JBW
10W Series Models.
II — SPECIFICATIONS
The following specifications are at nominal input voltages
and 25°C and apply to all models unless otherwise speci-
fied.
INPUT CHARACTERISTICS:
INPUT VOLTAGE: (0 to 100% load, -10 to 60°C)
Nominal 100-240V a-c, 220-240V a-c
Range: 85-265V a-c
INPUT SOURCE FREQUENCY:
Nominal:
50/60 Hz;
Range:
47-440 Hz
INPUT CURRENT: (100% load at 25°C with nominal out-
put voltage):
100V a-c input:
0.25 typ., 0.35 max.
240V a-c input:
0.15 typ., 0.25 max.
INPUT PROTECTION AND SOFT START: A thermis-
tor circuit reduces start-up surge. Units are protected
against shorts by an input fuse. Fuse value 2.0A, 250V.
INPUT SURGE: Cold start:
100V a-c input, 100% load: 15A typ, 20A max.
240V a-c input, 100% load: 30A typ., 40A max.
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, JBW 10W SERIES
MODEL
JBW 03-2R0
JBW 05-2R0
JBW 12-0R9
JBW 15-0R7
JBW 24-0R5
OUTPUT VOLTS, d-c
3.3V
5V
12V
15V
24V
SETTING TOLERANCE
3.14-3.46V
4.75-5.25V
11.4-12.6V
14.25-15.75V
22.8-25.2V
ADJUSTMENT RANGE
2.7-3.6V FIXED
FIXED
FIXED
FIXED
MAXIMUM
OUTPUT
RATINGS
50° C amb.
2.0A/6.6W (3)
2.0A/10W
0.9A/10.8W
0.7A/10.5W
0.5A/12W
60° C amb.
1.4A/4.6W
1.4A/7.0W
0.63A/7.56W
0.49A/7.35W
0.35A/8.4W
CURRENT LIMIT (AMPS)
3.0 min
2.5 min
1.12 min
0.87 min
0.62 min
OVP RANGE (VOLTS)
4.0 min
5.75 min
13.8 min
17.25 min
27.6 min
EFFICIENCY
100 Va-c
68%
71%
78%
79%
82%
240 Va-c
68%
71%
79%
80%
83%
ACCEPTABLE OUTPUT CAPACITOR
µFmax., (fixed load resistance)
10000
10000
5000
4000
2000
RIPPLE
AND
NOISE
(1)
(mV p-p)
ripple (typ)
80
80
120
120
120
ripple
-10-0°C, max
140
140
160
160
160
spike noise
(max)
(1)
120
120
150
150
150
spike noise
-10-0°C, max
(1)
160
160
180
180
180
(1)
Switching component approximately 100KHz, 0 to 100% load, 0 to 50 °C, tested with 100µF electrolytic and 0.1µF film capacitors across the measuring
points and connected to the power supply via 5.9 in (150mm) wires; oscilloscope bandwidth
≤
20MHz.
Document Outline
- I — INTRODUCTION
- Scope of Manual.
- Description.
- II — SPECIFICATIONS
- TABLE 1. Output Ratings And Specifications, JBW 10W Series
- Input Characteristics:
- Output Characteristics:
- Environmental Characteristics
- General Characteristics
- FIGURE 1. Output Power Vs. Temperature
- III — INSTALLATION
- Mounting Power Supply.
- Insulation.
- Ventilation.
- Connections.
- IV — OPERATION
- Protection Diode:
- FIGURE 2. Ventilation, Insulation and Mounting Direction
- FIGURE 3. Load Connections
- FIGURE 4. JBW 10W Mechanical Outline Diagram
- FIGURE 5. Input/Output connections