KEPCO HSF 300W Series (suffix A and AM) Operator Manuals User Manual
Page 7

HSF(A) 300W 101013
5
Insulation Resistance: (at 25°C,
65% relative humidity)
100 Megohms minimum (500Vdc)
Between output and ground, input and
ground, and input and output,
Humidity:
Operating: 10% to 90% relative humidity
Non-operating: 10% to 95% relative humidity
noncondensing,
Wet Bulb temperature <35°C
Vibration:
5-10 Hz., 10mm amplitude, 10-55 Hz., acceler-
ation 64.3ft./s
2
(19.6M/s
2
) (2g)
non-operating 1 hr. on each of 3 axes, sweep
time 10 minutes
Shock: Acceleration:
643.5ft./s
2
(196.1M/s
2
) (20g),
Pulse Duration: 11ms ± 5 msec
(non-operating, 1/2 sine pulse, three shocks
on each axis, Power Supply is fixed on its
bottom side)
Safety:
Designed to meet UL: 60950-1; CSA:C22.2
60950-1; EN60950-1; CE Mark.
Applies when input voltage is:
100 - 240V a-c, 50-60Hz
EMC Emission - Conducted:
Designed to meet FCC Class B, VCCI-Class B, EN55011-B, EN55022-B
EMC Emission - Radiated:
Designed to meet FCC Class B, VCCI-Class B, EN55011-B, EN55022-B
EMC Emission - Input harmonics
current:
Designed to meet EN61000-3-2
EMC Immunity
Designed to meet EN61000-6-2
EMC Radiated susceptibility:
Designed to meet EN61000-4-3 level 3
normal operation
EMC Conducted susceptibility:
Designed to meet EN61000-4-6 level 3
normal operation
ESD:
EN61000-4-2, level 3
normal operation
Electrical fast transient burst:
EN61000-4-4 level 3
normal operation
Surge withstand:
EN61000-4-5, level 3
No damage
Power Frequency Magnetic Field:
Designed to meet EN61000-4-8, level 4
(HSF 5-60AM: level 3)
normal operation
Voltage dips interruptions and
variations
EN61000-4-11
normal operation
Semi F47
200V a-c only
Dimensions:
5.22 in. (132.5 mm) x 4.288 in. (108.9 mm) x 16.86 in. (428.2 mm) (See Figure 3)
Mounting: Plug-in
Cooling:
Forced air flow - fan
Frame Material/Cover Material:
Steel
Weight
4.8 lbs, 2.18Kgs.
HSF 300 A models
5.3 lbs, 2.40Kgs.
HSF 300 AM models
TABLE 3. POWER SUPPLY RATINGS AND SPECIFICATIONS (CONTINUED)
CHARACTERISTIC
SPECIFICATION
CONDITION/NOTES