4 ecc-fft board layout, Ecc-fft board layout, Figure 1.1 back view of ecc-fft – Fire-Lite ECC-FFT Firefighters Telephone User Manual
Page 8: Dip switch

8
ECC-FFT Instruction Manual — P/N LS10031-000FL-E:B 9/4/2013
Product Description
ECC-FFT Board Layout
1.4 ECC-FFT Board Layout
Figure 1.1 above shows the circuit board that attaches to the cabinet. If you should need to remove
the board assembly for repair, remove the seven mounting nuts which hold the assembly in the cab-
inet. Then lift the control board out of the cabinet.
ON
1
234
5
6
S
L
C
OU
T
S
L
C
IN
P
H
O
N
E
OUT
P
H
ONE
IN
-
+
- +
- +
-
+
-
+
A
B
TROUBLE
NO
C
O
M
NC
1
2
3
4
Autoprogram
Accept
Status LEDs
Local Handset
piezo
Phone In
Phone Out
SLC IN
SLC Out
mounting stud
mounting studs
Supervised,
Power-Limited
All circuits are inherently power-limited
except the trouble relay
Not
Used
DC
Power
System Trouble Relay
Non Power-Limited
mounting studs
mounting stud
mounting stud
Figure 1.1 Back view of ECC-FFT
DIP Switch
fft
b
rd
.w
m
f
Power Status LED
- 2401B Circuit Board Standoff Placement (1 page)
- 411UDAC Fire Alarm Communicator (84 pages)
- 411UDAC Dig C Digital Communica unicatortor (1 page)
- 411UDAC Communicator Dress Panel (2 pages)
- 411UDAC Communicator Circuit Board & Transformer (2 pages)
- 411UDAC Fire Alarm Communicator Relay (1 page)
- ACC-25/50 Audio Command Center (1 page)
- ACC-25/50DA Distributed Audio Panel (84 pages)
- ACC-25/50ZS (1 page)
- ACM-16ATF Annunciator Modules (68 pages)
- ACM-8RF Control Relay Module (48 pages)
- APS-6RF Auxiliary Power Supply (28 pages)
- B524BI Plug-in Isolator (4 pages)
- B524RB(A) Plug-in Relay Detector Bases (4 pages)
- B310LP Plug-in Base for Addressable Detector (2 pages)
- B350LP Plug-In Base for Addressable Detector (4 pages)
- BB-55 Battery Box (1 page)
- BG-12 Series Manual Pull Stations (4 pages)
- BG-12LA Manual Pull Station (2 pages)
- BG-12LAO Manual Pull Station (2 pages)
- BG-12LO Manual Pull Station (2 pages)
- BG-12LPS Pre-Signal Manual Pull Station (2 pages)
- BG-12LR Agent Release Pull Station (2 pages)
- BG-12LX Addressable Pull Station (2 pages)
- BG-12SL Single Action Pull Station (2 pages)
- Central Station Receiver (1 page)
- CHG-120 Series Addendum - For Connection Of 100 Amp Hour Batteries (2 pages)
- CHG-120F Battery Charger (28 pages)
- CHG-75 Battery Charger (32 pages)
- CHS-6 Chassis (1 page)
- CHS-6 Chassis for BB-6 Cabinet (1 page)
- CMP-2401B Fire Alarm Control Panel (36 pages)
- CP355 Plug-in Addressable Ionization Sensor (2 pages)
- CRF-300 Relay Control Module (2 pages)
- DACT-UD2 Digital Alarm Communicator/Transmitter (52 pages)
- DP-4XF Dress Panel Kit PID (2 pages)
- ECC-50/100 Emergency Command Center (108 pages)
- ECC-50WBU Backup Amplifier (1 page)
- ECC-50DA/E Distributed Audio Amplifiers (26 pages)
- ECC-FFT (1 page)
- FCPS Series Field Charger/Power Supply (48 pages)
- FCPS Series Field Software Change Procedure (2 pages)
- FHSC-RF FIREFIGHTERS HANDSET STORAGE BOX (1 page)
- H350 Addressable Thermal Sensor (2 pages)