Vc stacking module installation, Overview, Preparation – Allied Telesis Layer 3 Gigabit Ethernet Switch x600-24Ts-POE User Manual
Page 72: Overview preparation, Figure 34. vc stacking (at-stackxg) module
Chapter 3: Installing the Hardware
72
VC Stacking Module Installation
Overview
When you are preparing the x600 switches for a VC Stack configuration,
the VC Stacking Module (AT-StackXG) must be installed in the expansion
slot on the rear panel of the unit. The AT-StackXG module is shown in
Figure 34.
Figure 34. VC Stacking (AT-StackXG) Module
Preparation
Review the following information before installing the AT-StackXG
Stacking Module:
The AT-StackXG Stacking Module is hardware hot-swappable. You
can install or replace the module while the switch is powered on.
Caution
If the stacking module is added or replaced in an operating stack,
the stack topology may change and cause the stack to reboot and
interrupt network traffic.
The AT-StackXG module is supported in all x600 series products and
requires software version 5.3.1 or later of AlliedWare Plus Operating
System Software.
Note
Do not install AT-StackXG module until you have read the latest
version of the AW+ Software Release Notes and the x600 Series
product documentation.