background image

Model 1000 H2S Echem

Model 1000 H2S Echem Instruction Manual

Rev. 2.8

Page 5 of 30

2. Specifications

Sensor Type

Electrochemical cell

Measurement Range

0-10ppm H

2

S, up to 0-5 % H

2

S

Accuracy/Repeatability

±10% of reading or ±0.5ppm, whichever is greater

Response/Clearing Time

T80 < 1 minute

Operating Temperature

-40°F to +122°F: -40°C to +50°C

Outputs

Linear 4-20mA DC; RS-485 Modbus™; 3 relays (alarm 1, alarm 2, and fault), Contacts rated 5 amps

Input Voltage

110~220VAC; 18~36VDC

Power Consumption

700mA (16.8 watts)

Electrical Classification

Explosion Proof; Class I, Division 1, Groups C, D

Sensor Life/Warranty

Sensor: 6 month conditional warranty; Transmitter: 2 year warranty

Analyzer Weight

70 lbs.

Dimensions

29” X 29” X 8”