5. Spare Parts


Part#

Description

325-400000-000

XHSSS CAM1 Explosion proof switch less contacts

3254-BT2

2 normally-open contact set for Explosion proof switch

283-1G0000-000

Power indicator lamp

283-1R0000-000

Flow fault indicator lamp

500-005151-002

Flow fault circuit assembly

351-011211-024

Dilution sample draw Pump 24VDC

350-009225-610

2000 ml/m flow meter with valve (air flow)

350-011210-610

250 ml/m flow meter with valve (sample flow)

360-6SD1SD-200 117VAC to 24VDC power supply assembly
823-600000-000

Moisture Knockout Assembly


6. Specifications

6.1 Sample Draw


Electrical Classification

NEMA 7 Explosion Proof

Dimensions

19.5"W x 22"H x 10"D

Power Input

110-VAC Standard

Operating Temperature Range -40°C to +65°C; -40°F to +149°F
Warranty One

year

6.2 Sensor Assembly

See Sensor Manual



7. Warranty

Detcon Inc., as manufacturer, warrants under intended normal use each new Model 971-071170-0DL Sample Draw to be
free from defects in material and workmanship for a period of one year from the date of shipment to the original
purchaser. Sensor assembly warranties are explained in their respective instruction manuals. All warranties and service
policies are FOB the Detcon Inc. facility located in The Woodlands, Texas.

971-071170-0DL Instruction Manual

Rev. 0.0

Page 6 of 8