2 base connector board, 3 explosion proof enclosure, Base connector board – Detcon DM-534C User Manual
Page 6: Explosion proof enclosure, Figure 3 base connector board
DM-534C Oxygen Sensor Assembly
DM-534C O2 Sensor Instruction Manual Rev.1.4
Page 2 of 18
1.2
Base Connector Board
The base connector board is mounted in the explosion proof enclosure and includes: the mating connector for
the control circuit, reverse input and secondary transient suppression, input filter, and lugless terminals for
field wiring.
Customer
Wiring
Wiring to
O2 Sensor
Figure 3 Base connector board
1.3
Explosion Proof Enclosure
The sensors are packaged in a cast metal explosion proof enclosure. The enclosure is fitted with a threaded
cover that has a glass lens window. Magnetic program switches located behind the transmitter module face
plate are activated through the lens window via a handheld magnetic programming tool allowing non-intrusive
operator interface with the sensor. Calibration can be accomplished without removing the cover or
declassifying the area. Electrical classification is Class I; Groups B, C, D; Division 1.