beautypg.com

Appendix, Specifications, 1 specifications – Detcon TP-624D User Manual

Page 41

background image

Model TP-624D

TP-624D Instruction Manual

Rev. 0.4

Page 37 of 40

9. Appendix

9.1 Specifications

Sensor Type:

Continuous diffusion/adsorption type
CHEMFET Solid State MOS type

Sensor Life:

5-10 years typical

Measuring Ranges:

0-20ppm, 0-50ppm, or 0-100ppm

Accuracy/ Repeatability:

± 2ppm or ±10% of applied gas (whichever is greater)

Response Time:

T50 < 30 seconds, T80 < 60 seconds

Outputs:

Linear 4-20mA DC
RS-485 Modbus™ RTU
3 Relays (Alarms 1, 2, and Fault)

Dry Contacts rated 5A

Electrical Classification:

Explosion Proof
CSA and US (NRTL)

Class I, Division 1, Groups B, C, D (Tamb= -40°C to 75°C)
Class I, Zone 1, Group IIB+H2

ATEX

EExd IIB+H2 T4 (Tamb= -40ºC ≤ Ta ≤ 60ºC)

Performance Approvals:

ISA 92.0.01 Part I-1998;
H2S Performance Requirements

Safety Approvals:

C

CSA

US

CSA/NRTL (US OSHA Certified)

FM

ATEX
CW Marking
SIL2 FMEDA Rating

Ingress Protection:

NEMA 4X, IP66

Applicable Standards

CSA C22.2 No. 30-M1986
CSA C22.2 No. 142-M1987
UL No. 916
UL No.1203
EN60079-0 (2006)
EN60079-1 (2007)

Warranty:

Electronics – 2 years
Sensor – 10 year conditional

Environmental Specifications

Operating Temperature:

-40°C to +75°C (-40°F to +167°F)

Storage Temperature:

-35°C to +55°C (-31°F to +131°F)