Appendix, 1 specifications – Detcon TP-700 User Manual
Page 39
Model TP-700
TP-700 Instruction Manual
Rev. 3.5
Page 35 of 38
9. Appendix
9.1 Specifications
Sensor Type:
Continuous diffusion/adsorption type
CHEMFET Solid State MOS type
True plug-in replaceable type
Sensor Life:
5-10 years typical
Measuring Ranges:
0-20ppm, 0-50ppm, 0-100ppm
Accuracy/ Repeatability:
± 10% of reading or ± 2ppm (whichever is greater)
Response Time:
T50 < 30 seconds, T80 < 60 seconds
Outputs
Linear 4-20mA DC
RS-485 Modbus™ RTU
Electrical Classification:
Explosion Proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb=-40° to 75°C)
Class I, Zone I, Group IIB+H2
ATEX
EEx d IIB+H
2
T4 (Tamb=-40° tp 75°C)
Ingress Protection
NEMA 4X, IP66
Safety Approvals:
cCSAus Complies with ISA92.0.01 Part 1-1998; Performance Requirements
for H2S
ATEX
CE Marking
SIL2 FMEDA Rating
Warranty:
Sensor – 10 year conditional
Transmitter – 2 years
Environmental Specifications
Operating Temperature:
-40°F to +167°F; -40°C to +75°C
FM ISA 92.0.01 Certi
fi
ed from -40°C to +65°C for H2S
Storage Temperature:
-31°F to +131°F; -35°C to +55°C
Operating Humidity:
5-100% RH (Non-condensing)
Operating Pressure Range:
Atmospheric ± 10%
Mechanical Specifications
Dimensions