beautypg.com

Cor poration, Xent a ur, Hazardous area safe area – COSA Xentaur Xentaur XDT User Manual

Page 63: Grounding bus bar

background image

XDT User’s Manual Appendices

56

Appendix N: Certifications - Approvals - Conformity (continued)

HAZARDOUS AREA

SAFE AREA

Shunt-diode

Safety Barrier

See Note B

1

2

3

4

75

Coaxial Cable

typically 12-20pF/ft.

Female BNC Connector

on Sensor Fitting, Cable

must have a Male BNC

Connector

. Polarity

back to

T

ransmitter

must be observed.

Grounding

Bus bar

Xentaur XTR-series

Dewpoint

Sensor Element

Revisions

Rev

Description

Date

Approved

T

OLERANCES:

(unless otherwise stated)

Decimal

.X = – .030

.XX = – .010

.XXX = – .005

Angular – 1 deg.

Do Not Scale Drawing.

Drawn:

B.B.

Material & Finish: (see Notes)

SIZE A

Scale: N/A

84F HORSEBLOCK RD.

Y

aphank, NY

1

1980

Date: 3/5/98

Sheet 1 of 1

Rev 5

Dwg. No. XDT

.00.D.6001

Control Drawing

for Entity Concept

Approved Installation

of Xentaur XTR-series Dewpoint Sensor

connected

to Associated Apparatus,

in Hazardous (Classified) Locations

XENT

A

UR

Cor

poration

IS Class I, Division 1, Group

A,B,C and D;

Class II Group E,F and G,

T6 at 60C and

A

TEX EEx ia IIC

T6

1

updated notes

5/6/98

BB

2

add MTL755ac

1

1/18/98

BB

3

added 9001zen.

6/30/99

BB

4

show sensor only

3/8/01

BB

5

A

TEX markings

1

1/28/04

BB

Associated Apparatus

Intrinsically Safe

Apparatus

Protective Component

Notes f

or installation in Nor

th America:

A.

Intr

insically Saf

e Entity P

ar

ameters:

V

max

= 10.03Vdc

, I

max

= 592mAdc

, C

i = 0.3uF

, L

i = 0mH.

B

. Selected Barr

iers m

ust be galv

anically isolated or dual channel shunt z

ener diode barr

iers with linear outputs

, used channe

l to channel and ha

ving entity par

ameters

such that

V

oc

<

V

max

, I

sc

< I

max

, C

a

> C

i + C

cab

le

, L

a

> L

i + L

cab

le

.

C

. F

or C

cab

le

and L

cab

le

, if the capacitance per f

oot or the inductance per f

oot is not kno

wn, then the f

ollo

wing v

alues shall be used:

C

cab

le

= 60pF/f

oot and L

cab

le

= 0.2uH/f

oot.

D

. Selected Barr

iers m

ust be installed in accordance with the barr

ier man

uf

acturer's control dr

a

wing and Ar

ticle 504 of the Na

tional Electr

ical Code ANSI/NFP

A 70.

E.

The XTR-Ser

ies sensor element does not pro

vide 500V isolation with respect to ear

th.

Notes f

or installation in Eur

ope:

Sensor

:

Xentaur XTR-series Dewpoint Sensor Element

EEx ia IIC

T6 DEMK

O Cer

tificate No

. 05 A

TEX 0505798X

A.

Intr

insically saf

e circuit par

ameters:

U

i :

10.03Vdc

, I

i :

592mAdc

, C

i :

0.3uF

, L

i :

0mH.

B

. Selected Barr

iers m

ust be galv

anically isolated or dual channel shunt z

ener diode barr

iers with linear outputs used channel

to channel and ha

ving entity par

ameters

such that U

o

< U

i, I

o

< I

i, C

o

> C

i + C

cab

le

, L

o

> L

i + L

cab

le

.

C

. F

or C

cab

le

and L

cab

le

, if the capacitance per f

oot or the inductance per f

oot is not kno

wn, then the f

ollo

wing v

alues shall be used:

C

cab

le

= 200pF/meter and L

cab

le

= 0.66uH/meter

.

D

.

The wir

ing of the intr

insically saf

e circuit ma

y be installed in accordance with EN60079-14 or

according to national installation requirements

.

E.

The XTR-Ser

ies sensor element does not pro

vide 500V isolation with respect to ear

th and

the leakage current is higher than 5mA.

The sensor shall be connected to PE ear

th or

installed such that it will satisfy a 500V dielectr

ic with respect to ear

th.

II 1 G