4 operating state, 1 viewing dewpoint mode, 4 operating state 3.4.4.1 viewing dewpoint mode – COSA Xentaur Xentaur XDT User Manual

Page 24: Dewpoint transmitter, Pushbuttons

background image

Section 3: Instrument

17

With a solid silk screened front face plate, which must be removed to access the circuit board
switches described above.

With a front face plate which has labeled holes placed immediately above the circuit board
switches, thus the operator may push the switches without removing the face plate, by making
use of a probe such as a paper clip.

With a front plate containing four membrane switches connected to the circuit board, provid-
ing the operator with a easy to use interface.

In general the MODE button navigates through the different user options “Modes”; the UP and
DOWN buttons modify the units, values or choices in the selected mode. Refer to the flow dia-
grams in Appendix A for detailed overview of button functionality. A button may be held down
for a prolonged time, for accelerated incrementing or decrementing of numeric values.

3.4.4 Operating State

Upon power up, the unit performs certain initialization tests (see table in section 3.6), and enters
the ‘Operating State’, in the Viewing Dewpoint mode. Depressing the ‘MODE’ button will
change modes (see appendix A) in the following order: nViewing Dewpoint oAlarms pStart
Calibration qViewing Serial Number (back to) nViewing Dewpoint. The unit will return to
Viewing Dewpoint mode if no buttons are pressed for 30 seconds, unless it is performing a cali-
bration.

3.4.4.1 Viewing Dewpoint Mode

When the instrument is powered on, it defaults to this mode. In addition, if the user navigates to
any other mode and ceases pressing the buttons for 30 seconds, then the instrument reverts to this
mode.
In this mode the user can view the dewpoint, this is indicated by the presence of the ‘DEW-
POINT’ legend on the lower left of the display. The available engineering units in which to view

LOW RELAY

HI RELAY

NC

NO

C

NC

NO

C

CAUTION

RELAY

VOLTAGE

o

o

GND

GND

10VA

50/60HZ

100-250VAC

J.F.M.A.M.J.J.A.S.O.N.D

2003

2002

2001

2000

S4

S3

S2

S1

R

S

R

P

E

D

O

M

MADE IN USA

XDT (C) 1999 XENTAUR CORP.

PS+

RET

RXD

TXD

A.OUT

A.RET

SIGNAL-RET

SIGNAL-IN

ACH

ACN

DEWPOINT TRANSMITTER

C

US

R

DEWPOINT TRANSMITTER

Remove front plate to access control buttons, consult the manual.

DEWPOINT TRANSMITTER

DEWPOINT TRANSMITTER

MODE

UP

DOWN

PRESSURE CORRECT

Use probe (paper clip) to push control buttons, consult the manual.

MODE

PRESSURE

CORRECT

CHOICES

VALUES

UNITS

UNITS

VALUES

CHOICES

Panel Mounted Instrument with a solid silkscreened face plate

Bare board, or Instrument opened for access.

Panel Mounted Instrument with a silkscreened face plate with holes

Panel Mounted Instrument with membrane switches

Pushbuttons