Appendix a: flow diagram of operating state user i, Xdt user’s manual appendices 35 – COSA Xentaur Xentaur XDT User Manual

Page 42

background image

XDT User’s Manual Appendices

35

Appendix A: Flow Diagram of Operating State User Interface

˚C

DEWPOINT

SET

SET
HI

HI/LO

SET
HI

SET
LO

SET
LO

SET
LO

SET
HI

SET

SET

SET

SET

SET

SET

SET

˚C

DEWPOINT

˚C

˚C

DEWPOINT

˚C

PSI

PSI

PSI

NUMBERS

CALCULATING

CALIBRATION

Legend: A slash '

/

' in the display area, is used to depict two alternately shown (flashing back and forth) messages.

denotes beeping. Buttons without designator or arrow leading out, perform no function

Scroll through Alarm activity options

LOC

-65.0

-B.X.F

-42.0

1.5Z

A.X.H

-65.0

2.0Z

CAL

XSN/123

END

SEN/2LO

AC/_AC

CNF/AC?

CAN

SEN/

GAS/

A.X.N -B.X.N A.X.H -B.X.H A.X.L -B.X.L A.X.F -B.X.F

VALUE

VALUE

{

{{

{

units

values

choices

Toggle Pressure Correction

Toggle 14.7 psi

Toggle 14.7 psi

SHORT PRESS

SHORT PRESS

LONG PRESS

LONG PRESS

SHORT PRESS

1/2 sec

LONG PRESS
AND PSI MODE

{

values

{

values

{

choices

{

values

{

values

{

{

Sensor

Reading

New calibration
values are saved

Cancel Calibration (it is not performed)

Confirm SpanCheck

Confirm
SpanCheck
again

1 minute

few sec

1 sec

OK

TOO LOW

Press together
to RESET the
instrument

values

go to
Set-Up
State

ignore error

see Self-Cal user
interface next page

When a third Alarm Relay is installed,
setup menu options will appear here
similar to Relays 1&2, but with both
the HI&LO legends active. This is
also the dewpoint alarm for units with
resetable Audio-Visual Alarm.

30 seconds anywhere (other than
"Calibration") without key press

appears when changing
settings of locked unit

Viewing Dewpoint

Set activity options

Set hysteresis

Set trigger dewpoint

Set activity options

Set hysteresis

Set trigger dewpoint

View/Set

Sensor

Pressure

View/Set

Gas

Pressure

Start

Calibration

Viewing

Serial-

number

Power ON initialization
and sign on message

Setting HI Alarm (Rela

y 1)

Setting LO Alarm (Rela

y 2)

Relay polarity:

A

= energize relay above trigger dewpoint

-B

= energize relay below trigger dewpoint

appropriate polarity selection in conjunction with
proper wiring wll provide fail safe operation

Fault reaction:

N

= faults do Not effect relays

H

= faults "look" like High dewpoint

L

= faults "look" like Low dewpoint

F

= faults Flash the relay

Flashing PSI indicates
pressure corrected
dewpoint

Displayed only if alarm options are installed

Flashing HI and/or LO

indicates corresponding

relays not energized