Installation:
Ensure that the sensor cavity of the flow meter is free of debris prior to installation.
Mount the HUB-40Ex into the sensor cavity and fasten threads. NOTE: REFER TO SECTION TITLED
installation instruction for use in Hazardous Area environments
REQUIREMENTS!
Slightly loosen Swivel Union nut and adjust the junction box in the desired orientation.
Tighten the Swivel Union nut while maintaining the orientation of the junction box. To properly seal surfaces from
external environment, apply 65 ft-lbs (+/- 4 ft-lbs) of torque. It is recommended to use anti-seize grease on threads to
avoid galling.
Remove conduit plug from the junction box to allow wire access, and remove the junction box lid to allow access to
terminal block connections.
Connect the wires to the appropriate terminals shown in the wiring guide.
Reapply the junction box lid until fully engaged and fasten setscrew.
Seal off conduit connection. NOTE: REFER TO SECTION TITLED
Special installation instruction for use in
FOR PROPER INSTALLATION REQUIREMENTS!
Wiring Guide: