OPERATION

SECTION 6

FIGURE 6A PNEUMATIC SCHEMATIC

6.2-1 REPRESSURIZATION STAGE

Repessurization occurs in the off-stream (regenerating) tower.

Repessurization must occur before tower changover to reduce shock

to the desiccant and the possibility of downstream pressure spikes.

Pilot valve SV1 or SV2 de-energizes causing the purge valve on the

off-stream (regenerated) tower to close. The purge air, which was

vented to atomosphere earlier in the cycle, is now used to

repressurize the off-stream tower.

6.2-2 CHANGEOVER/DEPRESSURIZATION STAGE

Tower changeover occurs after the off-stream (regenerated) tower is

pressurized. The SmartRelay signals SV1 or SV2 to open causing pilot

air to be supplied to the opposite side of the inlet transfer valve and

cause exhaust valve to open on regenerative tower. The inlet transfer

valve shuttle will move to the side that has pilot pressure placing the

regenerated tower on-stream. The tower that was on line and drying

the process air is now off-stream.

When the inlet transfer valve changes position, the position indicator

will move.

6.2-3 DRYING AND REGENERATION STAGE

One tower is on-stream (pressurized) drying process air. The process air

passes through the desiccant bed, which adsorbs moisture from the air.

The regeneration stage of the off-stream tower occurs at the same time

as the drying stage in the on-stream tower. During the regeneration

stage, a percentage of dry air is directed through the desiccant bed of

the offstream tower. The purge air is vented through the purge valve

to the atmosphere.

If pilot valve SV2 is energized, the LEFT tower is drying and if pilot

valve SV1 is energized, the RIGHT tower is drying.

6.3 MOISTURE INDICATOR

The moisture indicator is in the center of the panel. The moisture

indicator is a clear plastic tube filled with moisture sensing crystals. A

sample of outlet air is directed through the indicator.

The crystals will change colors from

PINK (indicating wet air) to

BLUE (indicating dry air) as the dew point of the air changes from

+20

O

F to -40

O