Van Air Systems FR-1200 User Manual
Page 3
![background image](/manuals/365758/3/background.png)
PAGE 3
3.1 SPECIFICATIONS
WEIGHT .............3200 Lbs (without desiccant installed)
4508 Lbs (with desiccant installed)
DIMENSIONS ..................... See SECTIONS 3.2
IN/OUT CONNECTION....... 3" 150# RF FLANGE
VESSELS (desiccant towers)
Construction ................... Manufactured to the ASME CODE, Section VIII, Division 1.
Vessels stamped "U" designator.
Design Pressure ............. 175 PSIG
Design Temperature ....... -20
O
F TO 300
O
F
PIPING
Threaded fittings: ........... ASME B16.3
Threaded unions: .......... ASME B16.39
Flanges: ......................... ASME B16.5
Welded Fittings ............... ASME B16.9
Pipe: .............................. Carbon steel, Schedule 40
VALVES
Inlet ............................... Proprietary 3-way piloted shuttle valve
Outlet .............................. Two (2) Check valves, wafer type
Purge .............................. Normally closed, air operatied type
CONTROL AIR FILTER
Construction ................... Aluminum housing
SEPARATOR/PREFILTER, PREFILTER, AFTERFILTER
Construction ................... Aluminum housing
PRE-COOLER
Core. ...............................Aluminum
Fan..................................Polypropylene blades with Aluminum hub
Fan Guard ......................Steel
ELECTRICAL
Standard 115 Volt ........... 115-120V/1PH/50-60Hz
DESICCANT
Material ........................... Activated Alumina, 1/8" (2-5 MM) Bead type
Quantity Per Tower ....... 654 Lbs.
OPERATING CONDITIONS
Inlet Air Pressure ............................ MIN 60 PSIG ...........MAX 175 PSIG
Inlet Air Temperature ...................... MIN 40°F.................MAX 150
O
F
Ambient Air Temperature................ MIN 40
O
F ................MAX 120
O
F
SYSTEM RATED INLET CONDITIONS
Inlet Air Pressure ............................ 100 PSIG
Inlet Air Temperature ...................... 150
O
F (based on 85°F ambient and 15°F approach from the pre-cooler)
Relative Humidity (saturation) ........ 100% RH
DRYER FLOW CAPACITIES (SCFM) at various pressures (100
0
F)
60 PSIG 80 PSIG 100 PSIG 110 PSIG 125 PSIG 140 PSIG 150 PSIG
160 PSIG
175 PSIG
FR-1200
782 990 1200 1251 1324 1394 1438 1481 1543
SPECIFICATIONS
SECTION 3