beautypg.com

Explanation of pump nomenclature, S15 non-metallic · design level 2· ball valve – SANDPIPER S15 Non-Metallic User Manual

Page 4

background image

520-193-000

9/02

Model S15 Non-Metallic Design Level 2 Page 2

Check

Diaphragm/

Check

Non-Wetted

Shipping

MODEL

Pump Pump

Valve

Design

Wetted

Check Valve

Valve

Material

Porting

Pump

Pump

Kit

Weight

Brand

Size

Type

Level

Material

Materials

Seat

Options

Options

Style

Options Options

lbs. (kg)

S15B2P1PQAS000.

S

15

B

2

P

1

P

Q

A

S

0

00.

53 (24)

S15B2K1KQAS000.

S

15

B

2

K

1

K

Q

A

S

0

00.

65 (29)

S15B2P2PQAS000.

S

15

B

2

P

2

P

Q

A

S

0

00.

53 (24)

S15B2K2KQAS000.

S

15

B

2

K

2

K

Q

A

S

0

00.

65 (29)

S15B2P3PQAV000.

S

15

B

2

P

3

P

Q

A

V

0

00.

58 (26)

S15B2K3KQAV000.

S

15

B

2

K

3

K

Q

A

V

0

00.

77 (35)

S15B2P4PQAV000.

S

15

B

2

P

4

P

Q

A

V

0

00.

58 (26)

S15B2K4KQAV000.

S

15

B

2

K

4

K

Q

A

V

0

00.

77 (35)

Pump Brand
S= SandPIPER II

®

Pump Size
15=1½"

Check Valve Type
B= Ball

Design Level
2= Design Level 2

Wetted Material
K= PVDF
P= Polypropylene

Diaphragm Check Valve
Materials
1= Santoprene/Santoprene
2= PTFE-Santoprene

Backup/PTFE

3= PTFE Pumping, PTFE-

Santoprene
Backup Driver/PTFE

4= Santoprene Pumping,

Santoprene
Driver/Santoprene

Check Valve Seat
K= PVDF
N= Nylon
P= Polypropylene

Non-Wetted Material Options
A= Painted Aluminum
J= Painted Aluminum PTFE
Q=Epoxy Coated Aluminum
K= PTFE Coated Aluminum
L= PTFE Coated Aluminum with

PTFE Coated Hardware

R= Epoxy Coated Aluminum with

PTFE Coated Hardware

Porting Options
A= ANSI Flange
D= DIN Flange
7= Dual Porting (ANSI)
8= Top Dual Porting (ANSI)
9= Bottom Dual Porting (ANSI)

Pump Style
D=RuppGUARD™ with Electronic

Leak Detection (110V)

E= RuppGUARD™ with Electronic

Leak Detection 220V)

M=RuppGUARD™ with Mechanical

Leak Detection

S= Standard
V= RuppGUARD™ with Visual

Leak Detection

Pump Options
0= None
1= 3M Muffler
2= Mesh Muffler
3= High temperature Air Valve

w/Encapsulated Muffler

4= High temperature Air Valve

w/3M Muffler

5= High temperature Air Valve

w/Mesh Muffler

Kit Options
00.=None
P0.=0-30VDC Pulse Output Kit
P1.=Intrinsically-Safe 10-30VDC

Pulse Output Kit

P2.=110/120 or 220/240VAC

Pulse Output Kit

P3.=Intrinsically-Safe 110/120VAC

Pulse Output Kit

P4.=Intrinsically-Safe 220/240VAC

Pulse Output Kit

E0.=Solenoid Kit with 24VDC Coil
E1.=Solenoid Kit with 24VDC Explosion-

Proof Coil

E2.=Solenoid Kit with 24VAC/12VDC Coil
E3.=Solenoid Kit with 24VAC12VDC

Explosion-Proof Coil

E4.=Solenoid Kit with 110VAC Coil
E5.=Solenoid Kit with 110VAC Explosion-

Proof Coil

E6.=Solenoid Kit with 220VAC Coil
E7.=Solenoid Kit with 220VAC Explosion-

Proof Coil

SP.=Stroke Indicator Pins

S15 Non-Metallic · Design Level 2· Ball Valve

Explanation of Pump Nomenclature