Available, as stated under principle of operation, is

an external output junction. If you wish to connect

the detection device to a solenoid which can shut

off air to the pump for example, or ring a bell, wire

into the box for this external connection thru the

7

/

8

"

diameter hole (commonly plugged) located on the

same end as the probe wire. The output connec-

tion terminal has 100 watt power output and each

FOR 220 VOLT UNITS:
Plug in only to 220 volt systems.

Do not have power to the cord

(do not have it plugged in) when

connecting to the box terminals.

CAUTION

FOR 115 VOLT UNITS:
Plug in only to 110 volt systems.

Do not have power to the cord

(do not have it plugged in) when

connecting to the box terminals.

CAUTION

FIGURE C

PROBE

CONNECTION TERMINAL

FOR 3 LEAD WIRE 15 ft. lg.

(P/N 150-026-000)

FROM ENCLOSURE BOX

(INCLUDED)

OUTPUT

CONNECTION TERMINAL

FOR POSSIBLE ALERT SYSTEM

OR TOTAL SYSTEM SHUT DOWN

(NOT INCLUDED)

(NOTE FIGURE “E”)

chamber has independent connections. If combining

the two chambers, a four-wire lead, spliced before the

external device would be necessary. (See output

connection terminal Figure E.)

When Leak Detector is used with spill containment

Models SET1-A and SET2-A, the probes must be fit-

ted into special boss plugs. Order one Boss Plug Kit

475-098-000 per pump.

ALMHI

ALMLO

ALMHI

LOAD

SW2

CH2

SW1

C3

CH1

ALMLO

P1

LOAD

ENCLOSURE

BOX

ENCLOSURE

LID

See FIGURE D

Page 5

PROBE PICKUP BOARD

MOUNTED ON THE

ENCLOSURE LID

POWER BOARD

MOUNTED ON THE BACK

OF ENCLOSURE

PICTOGRAM FOR FUSE

FU1 POWER PROTECTION

LINE

VOLTAGE

SELECT

INSERT SCREW DRIVER

IN SLOT AND SLIDE TO

CHANGE VOLTAGE

CAUTION: REMOVE

POWER FIRST

115/230VAC

50/60 Hz

DRY CONTACT

ALARM OUTPUTS

AC OR DC

220V/5A

MAX

OUTPUTS

C6

C5

TS2

C7

1

TS1

L1 L2 G

FU1

.5A

250V

P1

CR1

1

2

CR2

FU2

1A

250V

FU3

1A

250V

POWER

RTN

INC-

SENS

CW

R5

TS1

R6

INC-

SENS

CW

OPTIONAL EXTERNAL

OUTPUT JUNCTION

FOR SOLENOID

VALVES OR SIGNALS

PROBE

SENSITIVITY

ADJUSTMENT

ALMLO=ALARM ON

LOW CONDUCTIVITY

(HIGH RESISTANCE)

ALMHI=ALARM ON

HIGH CONDUCTIVITY

(LOW RESISTANCE)

115V

AC POWER TERMINAL

FOR POWER CORD

(NOT INCLUDED)

Options: