Installation

513005

20

1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.

Figure 17

3. Remove ground screw and save for use in Step 5.

Remove wire and use in Step 6.

Figure 18

4. Use a strain relief and insert end of power cord

through power supply hole.

Figure 19

5. Attach power cord ground (green) wire to rear

bulkhead using ground screw removed in Step 3.

Figure 20

6. Use the three screws from the accessories bag to

attach the remaining power cord wires to the

terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.

NOTE: When installing the white wire, loop the

free eyelet end of the ground wire (removed in

Step 3) and attach along with the white wire to the

neutral (center) terminal on the terminal block.

7. Tighten all screws firmly.

IMPORTANT: Failure to tighten these screws

firmly may result in wire failure at the terminal

block.

8. Secure the strain relief to the power cord, or

wires, where they enter the dryer cabinet.

9. Check the continuity of the ground connection

before plugging the cord into an outlet. Use an

acceptable indicating device connected to the

center grounding pin of the plug and the green

screw on the back of the cabinet.

10. Reinstall access cover and screw.

D695I

D697I

1

Ground Screw

D696I

D695I

D697I

1

DRY1920N

1

White

2

“L2” Terminal

3

Black

4

Green

5

Red

6

Neutral Terminal

7

“L1” Terminal

DRY1920N

5

7

1

2

4

6

3