Installation

11

513005

Exhaust System

For best drying results, recommended maximum

length of exhaust system is shown in Table 1.
To prevent backdraft when dryer is not in operation,

outer end of exhaust pipe must have a weather hood

with hinged dampers (obtain locally).

NOTE: Weather hood should be installed at least

12 inches (30.5 cm) above the ground. Larger

clearances may be necessary for installations where

heavy snowfall can occur.

Table 1

NOTE: The maximum length of a 4 in. (10.2 cm)

diameter flexible metal duct must not exceed

7.87 ft. (2.4 m), as required to meet UL2158, clause

7.3.2A.

Number of

90° Elbows

Weather Hood Type

Recommended

Use Only for Short Run installations

D673I

D802I

Maximum length of 4 in. (10.2 cm) diameter rigid metal duct.

0

65 feet (19.8 m)

55 feet (16.8 m)

1

55 feet (16.8 m)

47 feet (14.3 m)

2

47 feet (14.3 m)

41 feet (12.5 m)

3

36 feet (11.0 m)

30 feet (9.1 m)

4

28 feet (8.5 m)

22 feet (6.7 m)

NOTE: Deduct 6 feet (1.8 m) for each additional elbow.

4 in.

(10.2 cm)

4 in.

(10.2 cm)

2-1/2 in.

(6.35 cm)