VIPER

B-3

OPERATION

B-3

CUTTING CAPABILITY

The VIPER is rated at 55 amps, at 50% duty cycle on a 10 minute basis or 40 amps, at 100% duty cycle. If the
duty cycle is exceeded, a thermal protector will shut off the output of the machine until it cools to the normal oper-
ating temperature.

Figure B.1 shows the cut capacity of the VIPER when cutting mild steel. The graph plots cut thickness vs. torch
travel speed with a torch standoff of 0.15". Example: 0.25” material may be cut at a setting of 35 amps at an
approximate speed of 38 IPM or at a setting of 45 amps at an approximate speed of 57 IPM or at a setting of 55
amps at an approximate speed of 62 IPM.

VIPER

Mild Steel Cut Capacity Chart

Recommended T

orch T

ravel

Speed

(IPM)

80% of Maximum Speed

100

80

60

40

20

0

0.000"

0.125"

0.250"

0.375"

0.500"

0.625"

0.750"

Material Thickness

25 A

35 A

45 A

55 A

Figure B.1

CONSUMABLE LIFE

The expected life for the VIPER's electrode under normal operating conditions is approximately 320 starts/cuts.
An erosion of .060" is typical for end of electrode life, however, the electrode life may last longer. A green and
erratic arc will indicate definite electrode failure and the electrode should be replaced immediately.

It is recommended that consumables be replaced in complete sets. (Example: Electrode and Nozzle). This will
maximize the performance of the VIPER system.