beautypg.com

Diagrams – Lincoln Electric IM980 RED-D-ARC EX350ie (CE) User Manual

Page 28

background image

F-4

DIAGRAMS

F-4

EX350ie (CE) (RED-D-ARC)

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",

REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE.

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

TO

WORK

-

+

14 PIN

AMPHENOL

N.C.

76

82

K867 UNIVERSAL

ADAPTER PLUG

81

SPARE

2

4

41

42

31

32

GND

21

77

75

REMOTE OUTPUT CONTROL

NOT USED ON POWER SOURCE

CONNECT TOGETHER FOR WELDING OUTPUT

24 VAC / 5.5 AMP

24 VAC / 5.5 AMP

42 VAC / 5.5 AMP

115 VAC / 2 AMP

POWER SOURCE FRAME CONNECTION

N.D.

N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION

RELAY TO CLOSE LEADS 2 & 4.

2

4

TO

K867

ELECTRODE CABLE

WIRE FEEDER VOLTMETER CONNECTION

CONNECTS TO (WORK TERMINAL) OF POWER SOURCE

TO

WIRE FEEDER

10K

MIN.

Only qualified persons should install, use or

service this machine.

using the disconnect switch at the fuse box

WARNING

Turn off input power to the Welding Power Source

Before connecting the wire feeder.

ELECTRIC

SHOCK

CAN KILL

POWER SOURCE

WITH 115VAC

AUXILIARY POWER

S24985

3-1-00