Installation, Technical specifications – Lincoln Electric IM980 RED-D-ARC EX350ie (CE) User Manual
Page 10

EX350ie (CE) (RED-D-ARC)
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS -
EX350ie (CE) (RED-D-ARC)
INPUT AT RATED OUTPUT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
CURRENT
LENGTH UP 61m (200 FT)
61-76m (200-250 FT)
100%
275
1/0
1/0
60%
350
1/0
2/0
Voltage
200
220
380
400
415
440
Phases
1
1
1
1
1
1
Input Amps
275 Amps @
31Volts(100%)
Not
Recommended
64
44
40
38
35
Input Amps
320 Amps @
33Volts(60%)
Not
Recommended
82
55
50
48
45
Line Cord
AWG
---
4
6
8
8
8
Maximum
Fuse size
---
125A
80A
80A
80A
80A
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Note 1. Not rated is indicated by 4-xʼs in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Notes
Note 1
Note 2
Note 2
*
Overall Length Including Handle, 27.8” (706mm)
Height
Width
Depth
Weight with Cord
14.8”(373mm)
12.5”(317mm)
27.8” *(706mm*)
86.5 Lbs.(37.4 Kg)
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
STORAGE TEMPERATURE RANGE
-40°C to +40°C
OPERATING TEMPERATURE RANGE
-20°C to +40°C
Voltage
200
220
380
400
415
440
Phases
3
3
3
3
3
3
Input Amps
300Amps @
32Volts(100%)
41
37
28
22
22
21
Input Amps
350Amps @
34Volts(60%)
48
48
28
27
26
24
Line Cord
AWG
6
6
8
8
8
8
Maximum
Fuse size
80A
80A
50A
50A
50A
50A
Input 50/60 Hz
Recommended
Recommended
Notes
Note 2
Note 2
Product
Name
EX350ie
(CE)
50/60 Hz
Ordering
Informatiion
K1757-3
Input AC
Voltage
200-220/
380-400/
415-440/
Output
Range
(continuous)
AMPS
5-425
Open
Circuit
80 VDC
Rated DC Output
Amps/Volts/Duty Cycle
50/0Hz
350A / 34V / 60%
3 Phase
320A / 38V/ 60%
1 Phase
275A /31V / 100%
1 Phase
300A / 32V / 100%
3 Phase