OPERATION

B-7

AUXILIARY POWER:

Start the engine and set the IDLER control switch to the
desired operating mode. Full power is available regard-
less of the welding control settings providing no welding
current is being drawn.

Simultaneous Welding and Auxiliary Power Loads

While welding, the amount of 3-phase Auxiliary power
available is reduced.

TABLE B.4

RANGER 305D (CE)

WELDING OUTPUT-

AMPS

0

50

100
150
200
250

PERMISSIBLE POWER-WATTS

(UNITY POWER FACTOR)

8000

6500
5000
3500
2000

0

PERMISSIBLE AUX

POWER @400V, 3PHASE

12 Amps

9 Amps
7 Amps
5 Amps
3 Amps