beautypg.com

Installation – Lincoln Electric IM813 RANGER 305 D (CE) User Manual

Page 13

background image

RANGER 305D (CE)

(1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding,

available auxiliary power will be reduced.

(2) To top of enclosure, add 152mm (6 “) to top of exhaust elbow.
(3) Engine warranty may vary outside of the USA. (See Engine warranty for details)
(4) Center-Tapped to ground.

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - RANGER 305D (CE) K2279-1 & K2279-2

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

cu. in. (cu. cm.)

System

3 cylinder

43.88(789)

12VDC Battery & Fuel:

4 stroke

starter 45L (12 US.gal.)

15.9 HP

High Idle 3100 Bore x Stroke inch (mm)

Oil:

Kubota

(3)

(12 KW)

3.2L(3.4 US. Qts.)

D722 Net intermittent

Full Load 3000

2.64 x 2.68

(Group 58; 550 Radiator Coolant:

3000 RPM

(67 x 68 mm)

cold crank amps) 3.6L(3.85 U Qts)

naturally aspirated Low Idle 2200

Battery Charger

water cooled engine

(3.6L)

INPUT - DIESEL ENGINE

RATED OUTPUT @ 40° C (104° F) - WELDER

HEIGHT WIDTH

DEPTH

WEIGHT

909mm 546mm 1524mm

30.0 in.

(2)

21.50 in

60.0 in.

LUBRICATION EMISSIONS

FUEL SYSTEM

GOVERNOR

Full Pressure

Electric Fuel Pump, Auto air bleed system

with Full Flow Filter Certified to EPA Tier I

Electric shutoff solenoid

Mechanical Governor

Indirect fuel injector

AIR CLEANER

ENGINE IDLER

MUFFLER

ENGINE PROTECTION

Low noise Muffler:

Shutdown on low oil

Single Element

Automatic Idler

Top outlet can be rotated. pressure & engine

Made from long life, aluminized steel.

temperature

ENGINE WARRANTY: 2 year complete (parts and labor) 3rd. year major components (parts and labor)

(3)

Welding Process

DC Constant Current

DC Pipe Current

Touch-Start™TIG

DC Constant Voltage

Output Range

20 TO 305 AMPS
40 TO 300 AMPS
20 TO 250 AMPS

14 TO 29 VOLTS

Max. Weld OCV

@Rated Load RPM

60 Volts

Welding Output

Current/Voltage/Duty Cycle

250A / 30V / 100%
250A / 30V / 100%
250A / 20V / 100%
250A / 27V / 100%

Auxiliary Power

(1)

8,500 Watts Peak, / 8,000 Watts Continuous, 50 Hz 115 & 230 Volts - 1 Phase

8,500 Watts Peak, / 8,000 Watts Continuous, 50 Hz 400 Volts - 3 Phase

Sound Levels

Sound Power: 98 dB Lwa

PHYSICAL DIMENSIONS

ENGINE

MODEL NUMBER

Receptacles

Residual Current Device (RCD)

Circuit Breakers (Thermal/Magnetic)

K2279-1 (UK)

400V (3 Ph) x 1
230V (1 Ph) x 1

115V x 1

(4)

14 Pin Connector

6 Pin Connector

4-pole, 25 Amp

(30mA trip current)

3 Phase, 20 Amp x 1
1 Phase, 15 Amp x 5

K2279-2 (EUROPE)

400V (3 Ph) x 1

230V (1 Ph) x 2

14 Pin Connector

6 Pin Connector

4-pole, 25 Amp

(30mA trip current)

3 Phase, 20 Amp x 1
1 Phase, 15 Amp x 4

RATED OUTPUT @ 40° C (104° F) - GENERATOR

341kg. (752lbs.)