beautypg.com

Installation – Lincoln Electric IM944 POWERTORCH PLASMA 20 User Manual

Page 7

background image

A-1

INSTALLATION

A-1

Weight

Including

Torch Cable

21 lbs.

9.5 kg.

INPUT - SINGLE PHASE

RATED OUTPUT

OUTPUT

RECOMMEND INPUT WIRE AND FUSE SIZES

REQUIRED AIR FLOW RATE

REQUIRED AIR INLET PRESSURE

PHYSICAL DIMENSIONS

TECHNICAL SPECIFICATIONS - POWERTORCH™ PLASMA 20 (K2682-1)

Standard Voltage

Duty Cycle

50% on 115V (15 Amp Branch)

40% on 115V (20 Amp Branch with 20 Amp Plug*)

Current

Range

10-20 Amps

115V-1Ø

115V-1Ø

20 Amps

15 Amps

Depth

16 in.

406 mm

Width

6 in.

152 mm

Height

12 in.

305 mm

Open Circuit

Voltage

310 VDC

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30

o

C or Less

Pilot Current

17 Amps

AMPS

15 A

20 A

1Ø Input Current at Rated Output

115/1/50/60Hz (15 Amp Branch)

115 V: 20A @ 50%

115 V: 26A @ 40%

3.5 cu. ft./min.

(100L/min.)

72.5 to 150 PSI

( 5 Bar TO 10.3 Bar)

20 A

15 A

Output

Plug Size

POWERTORCH™ PLASMA 20

115/1/50/60Hz (20 Amp Branch with 20 Amp Plug*)

AC Input

Voltage

at

50/60

Hertz

Maximum

Time-Delay

Circuit Breaker

or Fuse Size

5-20P*

5-15P

Type SJT or Hard Usage

Input Cord

3 Conductor, #14 AWG

*

5-20P plug must comply with the standard for attachment plugs and receptacles, UL498.