E-5

TROUBLESHOOTING

E-5

PIPELINER 200G

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Engine Stops During Operation and
the Engine Protection Light

Does

Turn On. (Flashing)

White or Blue Smoke.

Dark Smoke

Faulty Charging

Starter Motor does not run.

Engine Knocking.

Lack of Power.

1. Lack of Coolant.
2. Loose or slipping fan belt.
3. Damaged fan belt.
4. Clogged radiator.
5 Clogged radiator fan.
6. Dust or scale clogged in the cool-

ing water passage.

7. Faulty function in the thermostat.
8. Overloading.
9. Faulty TBI controller.

1. Excess engine oil.
2. Too low viscosity of the engine oil.

1. Excess injection.
2. Clogged air cleaner.
3. Faulty function of the engine.

1. Loose fan belt.
2. Faulty wiring.
3. Faulty battery.
4. Worn out alternator brush.

1. Loose or damaged wiring.
2. Low Battery voltage.
3. Damaged starter motor.

1. Poor grade of Gasoline.
2. Spark advance to far.

1. Carbon deposits causing pre-igni-

tion.

2. Incorrect timing.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Lincoln
Authorized Field Service Facility.