Installation, Warning caution, A-2 safety precautions – Lincoln Electric IM761 POWER FEED 15M User Manual
Page 9: Location, High frequency protection, Connection diagrams

A-2
INSTALLATION
POWER FEED 15M
A-2
SAFETY PRECAUTIONS
ELECTRIC SHOCK CAN KILL.
• ONLY QUALIFIED PERSONNEL
SHOULD PERFORM THIS
INSTALLATION.
• Turn off input power to the power
source at the disconnect switch or
fuse box before working on this
equipment. Turn off the input power to any other
equipment connected to the welding system at
the disconnect switch or fuse box before
working on the equipment.
• Do not touch electrically hot parts.
-------------------------------------------------------------------
LOCATION
The Power Feed 15M has an IP23 rating, suitable for
outdoor use.
The Power Feed 15M should be positioned upright on
a horizontal surface. Do not submerge the Power
Feed 15M in water. The best practice is to keep the
wire feeder in a dry environment. When working
outdoors in severe wet weather, place the Power Feed
15M with the door facing up.
HIGH FREQUENCY PROTECTION
Locate the Power Feed 15M away from radio con-
trolled machinery. The normal operation of the
Power Feed 15M may adversely affect the operation
of RF controlled equipment, which may result in
bodily injury or damage to the equipment.
----------------------------------------------------------------------------
WARNING
CAUTION
Digital Control Cable
Work
Cable
Electrode Cable
Power Source
Wire Feeder
+
-
Welding Gun
Shielding
Gas Hose
Shielding
Gas Hose
Digital Control Cable
W ork
Connec tion
Coaxial Weld Cable
Power Sourc e
Wire Feeder
+
-
Welding Gun
CONNECTION DIAGRAMS
CV Welding:
Figure A.1
Pulse Welding or STT Welding:
Figure A.2