Troubleshooting, Caution – Lincoln Electric IM761 POWER FEED 15M User Manual
Page 36

POWER FEED 15M
E-2
TROUBLESHOOTING
E-2
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.
CAUTION
Fault Code
Err 006
Err 100
Err 31 Primary overcurrent.
Err 32 Capacitor bank "A"
under voltage.
Err 33 Capacitor bank "B"
under voltage.
Err 34 Capacitor bank "A"
overvoltage.
Err 35 Capacitor bank "B"
overvoltage.
Err 41 Long term secondary
overcurrent.
Description
1. The wire feeder has not received
a recognition command from the
power source. The power source
has issued a shutdown command.
1. The power source has issued a
shutdown command.
1. The power source has exceeded
input current limits.
2. See the power source Instruction
Manual.
1. The power source input power
may be wired incorrectly.
1. The power source input power
may be wired incorrectly.
1. The power source input power
may be wired incorrectly.
1. The power source input power
may be wired incorrectly.
1. The power source has exceeded
the output current limits.
2. See the power source Instruction
Manual.
Possible Adjustments
1. Verify the power source is operat-
ing properly (Status light steady
green.)
2. Check control cable for loose or
broken leads.
3. See power source Instruction
Manual.
1. Verify the power source is operat-
ing properly (Status light steady
green.)
2. Check control cable for loose or
broken leads.
3. See power source instruction
Manual.
1. Adjust the welding procedure to
reduce the current draw. The
welding procedure may exceed
the capacity of the power source.
1. Verify the power source reconnect
panel wiring matches the input
power.
2. See the power source Instruction
Manual.
1. Verify the power source reconnect
panel wiring matches the input
power.
2. See the power source Instruction
Manual.
1. Verify the power source reconnect
panel wiring matches the input
power.
2. See the power source Instruction
Manual.
1. Verify the power source reconnect
panel wiring matches the input
power.
2. See the power source Instruction
Manual.
1. Adjust the welding procedure to
reduce the current draw. The
welding procedure may exceed
the capacity of the power source.
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS
RECOMMENDED
COURSE OF ACTION
Linc-Net System Error Codes
ArcLink System Error Codes