CONTROL CABLE CONNECTION:
Digital Control Cable: Figure A.3
Welding Gun/Wire Feeder Trigger Connector
Wire Feeder: Figure A.4
WELD CABLE SIZE
Table A.1 located below are copper cable sizes rec-
ommended for different currents and duty cycles.
Lengths stipulated are the distance from the welder to
work and back to the welder again. Cable sizes are
increased for greater lengths primarily for the purpose
of minimizing cable drop.
Power Source
A
B
C
D
E
Wire Feeder
A
B
C
D
E
Power Source
Pin
Function
A
Digital I/O
B
Digital I/O
C
"67" voltage sense
D
40 VDC
E
40 VDC
Wire Feeder
Pin
Function
A
Digital I/O
B
Digital I/O
C
"67" voltage sense
D
40 VDC
E
40 VDC
WIRE FEEDER
Pin Function
A Gun Trigger
B -
C Common
D Dual Procedure
E Common
Wire Feeder
Welding Gun
A
B
C
D
E
** Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables
larger than recommended, or cables rated higher than 167°F(75°C).
RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 167°F or 75°C)**
CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES
AMPRERES
200
200
225
225
250
250
250
250
300
325
350
400
400
500
PERCENT
DUTY
CYCLE
60
100
20
40 & 30
30
40
60
100
60
100
60
60
100
60
0 to 50Ft.
(0 to15M)
2
2
4 or 5
3
3
2
1
1
1
2/0
1/0
2/0
3/0
2/0
50 to 100Ft.
(15 to 30M)
2
2
3
3
3
2
1
1
1
2/0
1/0
2/0
3/0
2/0
100 to 150 Ft.
(30 to 46M)
2
2
2
2
2
1
1
1
1
2/0
2/0
2/0
3/0
3/0
150 to 200 Ft.
(46 to 61M)
1
1
1
1
1
1
1
1
1/0
2/0
2/0
3/0
3/0
3/0
200 to 250 Ft.
(61 to 76M)
1/0
1/0
1/0
1/0
1/0
1/0
1/0
1/0
2/0
3/0
3/0
4/0
4/0
4/0
TABLE A.1