Maintenance, Routine maintenance, Warning – Lincoln Electric IM667 Mobiflex 400-MS User Manual
Page 17
MOBIFLEX 400-MS
C-1
MAINTENANCE
C-1
ROUTINE MAINTENANCE
Every 3 months, clean the inside of the machine with
a vacuum cleaner, including the filter compartment
and spark arrester. Check the filter for damage or sat-
uration. Every 12 months, have a qualified technician
check the blower fan and housing for encrusted parti-
cles and clean if necessary. Check the sealing materi-
al of the extraction fan and replace if necessary.
EMPTYING THE DUST DRAWER
The particulate matter collected may be dangerous to
your health. Take necessary precautions so that you
and your fellow workers do not breathe the dust and
particulate. Wear a suitable respirator when disposing
of the particulate.
Check with local authorities for regulations governing
the disposal of this material.
------------------------------------------------------------------------
Periodically check the dust drawer to see if it is full.
Turn off the Mobiflex 400-MS and disconnect it from
power. Access the drawer by loosening the thumb
screw underneath the drawer at the back of the
machine (Fig. 16, Item B). When this screw is
released, the drawer (Fig. 16, Item A) will drop down
and slide out. SEE WARNINGS ABOVE.
Check with local authorities for regulations governing
the disposal of this material. SEE WARNINGS
ABOVE.
REPLACING THE FILTER CARTRIDGE
AND CLEANING THE SPARK ARRESTER
Replace the filter when it has been damaged or when
the indicator shows that the filter is clogged. The filter
indicator will flash if the cleaning function does not
reduce the pressure drop below the set point after two
cleaning pulses. This could be due to a saturated filter,
lack of compressed air, low air pressure or cleaning
equipment malfunction. If the filter is saturated, replace
the filter.
The particulate matter collected may be dangerous to
your health. Take necessary precautions so that you
and your fellow workers do not breathe the dust and
particulate. Wear a suitable respirator when disposing
of the particulate.
Check with local authorities for regulations governing
the disposal of this material.
1.
Disconnect the machine from input power.
2.
Unscrew the thumb nut (Fig. 17, Item A) and
remove the filter cover (Fig. 17, Item B).
3.
Lift the filter cartridge up and out of the machine.
4.
Unscrew the mounting screws on the corners of
the spark arrestor.
5.
Lift the spark arrestor up and out of the machine.
Clean the spark arrester and filter compartment
with a vacuum cleaner.
6.
Replace the spark arrester and install the new filter
and replace the filter cover and thumb nut.
WARNING
WARNING
FIG. 16