B-6

OPERATION

B-6

LN-25™ PRO DUAL POWER

WFS CALIBRATION WITH DIGITAL
METERS (K2613-4, K2614-1, -2 & -3 )

To calibrate the wire feed speed, before entering the
set-up menu:

Set the display to the desired wire feed speed (exam-
ple: 400 inches per minute)

Measure the actual wire feed speed (example: 405
inches per minute)

While in the set-up menu, adjust the calibration factor
as follows:

Actual WFS

405

Set WFS

400

Press the set-up button to exit the set-up menu.

=Calibration Factor Example

=1.01