PAGE 25 OF 27
3.3.6.9
Command Name
Command Description
PrefetchNumber
Use this command to assign the maximum pre-fetch number.
Parameter 1
Parameter Description
Pre-fetch Number:
<1:2:4:8:16:32:64:128>
Pre-fetch Number:
The basic unit of maximum pre-fetch number is one stripe. For
example, if the maximum pre-fetch number is 8 and the stripe size is
128KB, then the maximum pre-fetch size is 8x128KB.
3.3.6.10
Command Name
Command Description
DriveCacheMode
Use this command to enable or disable drive cache(s).
Parameter 1
Parameter Description
Drive No.:
Parameter 2
Switch setting:
Drive No.:
Specify a drive or all drives to enable or disable cache.
<1~n>, where n stands for maximum existing drive number.
Drive=All, the command will have effect on all existing drives.
Switch setting:
Enable or disable the cache(s) on the specified drive(s).
3.3.6.11
Command Name
Command Description
CtrlTime
Use this command to set controller time.
Parameter 1
Parameter Description
Year:
Parameter 2
Month:
Parameter 3
Day:
Parameter 5
Hour:
Parameter 6
Minute:
Parameter 7
Second:
Year: