Vt6420 user manual – sata controller – Elitegroup P71EN installation User Manual
Page 18

VT6420 User Manual – SATA Controller
Revision 1.01, May 19, 2003
14
BIOS Configuration Utility
1. Power off and Check the Failed Drive:
This item turns off the computer and replaces the failed hard drive with a good one. If your computer does not support APM,
you must turn off your computer manually. After replacing the hard drive, boot into BIOS and select Choose replacement
drive and rebuild to rebuild the broken array.
2. Destroy the Mirroring Relationship:
This item cancels the data mirroring relationship of the broken array. For broken RAID 1 arrays, the data on the surviving disk
will remain after the destroy operation. However, Destroy the Mirroring Relationship is not recommend because the data on
the remaining disk will be lost when the hard drive is used to create another RAID 1 array.
3. Choose Replacement Drive and Rebuild:
This item enables users to select an already-connected hard drive to rebuild the broken array. After choosing a hard drive, the
channel column will be activated.
Highlight the target hard drive and press
press N to cancel. Please note selecting option Y will destroy all the data on the selected hard drive.
4. Continue to boot:
This item enables BIOS to skip the problem and continue booting into OS.