Switch is off position
Blown fuse
Tripped breaker
Disconnected plug
Corroded plug
Float obstructed
Defective switch*
Defective motor
Low water level
Tripped thermal protection
*
To confirm a switch failure, simply unplug
the pump from the piggy back receptacle
and plug the pump directly in the wall
receptacle.
Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller
Check valve installed backward
Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller
Clogged check valve
Defective switch
Missing check valve
Clogged check valve in open position
Float obstruction
Clogged inlet
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where
you’ve purchased the pump, please contact us at 514 337-4415, and ask for our
sales department, and they will be pleased to help you with any question you
might have, concerning your installation.
Turn switch to on position
Replace
Reset
Re-install
Clean
Remove obstruction and verify movement
Replace
Replace
Add water and check
Motor will reset automatically after 15
minutes
Check voltage
Check drilled hole in discharge pipe and
clean it
Improper pump selection (over 15')
Clean
Install in proper position with the flap
pointing upward
Check voltage
Check drilled hole in discharge pipe and
clean it
Improper selection (over 15')
Clean pump base
Clean or replace
Replace
Install valve
Clean debris
Remove obstruction and verify movement
Clean pump base
Motor does not
run.
Motor runs but
no water is
delivered.
Pump does not
deliver to full
capacity.
Pump does not
shut off.
TROUBLE SHOOTING GUIDE CHECLIST :
TROUBLE PROBABLE
CAUSE
ACTION
NEVER MAKE ADJUSTEMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED.
DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE.