Installing the application
1
For UNIX system, if you still receive error messages after closing the application, enter the
following commands:
#ps -ef | grep -i “”
to list the process IDs
#kill -9 “
Process_ID” where Process_ID is any Management application process
Additional pre-installation requirements for UNIX systems
•
Make sure that an X Server is available for display and is configured to permit X Client
applications to display from the host on which they are installing the Network Advisor server
(typically, this simply requires that the systems console be present and running with a
logged-in user on the X Server-based desktop session, such as KDE, GNOME, and so on).
If this is a headless unit with no console, refer to
“Additional pre-installation requirements for
UNIX systems (headless installation)”
•
Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid
value (for example, to display to the local console, export DISPLAY=:0.0, or to display to a
remote system that has an X Server running, export DISPLAY=Remote_IP_address:0.0).
You may also need to consider a firewall that might block the display to the X Server, which
listens by default on TCP port 6000 on the remote host.
To display to a remote system, you need to permit the remote display of the X Server by running
the xhost +IP command, where IP is the IP address of the Network Advisor server host
from the X-based desktop of the remote system.
•
Make sure you test the DISPLAY definition by running the xterm command, from the same
shell from which you run install.bin. A new X terminal window to the destination X Server
display should open.
•
For Linux OS with the SELinux security policy enabled, make sure you complete the following
steps.
1. Disable the SELinux security policy using the
setenforce 0
command.
2. Install the application (refer to
3. Enable the SELinux security policy using the
setenforce 1
command.
Installing the application
Before you install the application, make sure your system meets the minimum pre-installation
requirements (refer to
“Pre-installation requirements”
on page 8). If you are migrating data, refer to
NOTE
SAN with SMI Agent + IP is not supported on 32-bit Windows
systems. For more information, refer to
NOTE
On Windows systems, you must be an Administrator with Read and Write privileges to install Network
Advisor.